Alarm, fault and system messages
11.4 I/O device diagnostics
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
349
Diagnostics data record SFB 54
Byte
Value
Meaning
0 ... 1
according to PNIO standard
Block type
2 ... 3
W#16#001A / W#16#0016
Length of the diagnostics data with an incoming / outgoing alarm.
4 ... 5
W#16#0100
Version (fixed)
6 ... 7
W#16#0001 / W#16#000C
ID for the alarm type: Diagnostics alarm incoming / diagnostics alarm
outgoing.
8 ... 11
DW#16#00000000
API (fixed)
12 ... 13
W#16#0000
Slot (fixed)
14 ... 15
W#16#0001
Subslot (fixed)
16 ... 19
DW#16#00000300
Module identification (fixed)
20 ... 23
DW#16#00000000
Submodule identification (fixed)
24 ... 25
W#16#Bxxx / W#16#xxx
Alarm specification for incoming / outgoing alarm:
•
Bits 0 to 10: Sequence number
•
Bit 11: Channel diagnostics: 0 (fixed)
•
Bit 12: Status of vendor-specific diagnostics
•
Bit 13: Status of diagnostics for submodule
•
Bit 14: Reserved: 0
•
Bit 15: Diagnostics status
26 ... 27
W#16#0004
ID for vendor-specific diagnostics (fixed).
28 ... 29
Value from the table under error
messages
ID of the error that occurred.
In contrast to events-related reading out of the diagnostics data with SFB 54, there is also
the option of reading out the diagnostics data status-related.
You read out status-related diagnostics data using SFB 52 "RDREC".
Calling SFB 52:
1.
You assign the diagnostics address of the reader to the ID parameter in hexadecimal
format.
2.
Assign the value 2 to the INDEX parameter.