Process interfacing via an automation system (PLC, PC)
10.4 Control with FB79
SIMATIC MV420 / SIMATIC MV440
274
Operating Instructions, 04/2013, A5E02371045-06
Data to be read
consists of ...
Data type of each component
Position of the data matrix code
Note:
Viewing angle is only output for
DMC quality = ambitious
•
X position
•
Y position
•
Roll angle
•
Viewing angle
INT
Absolute quality characteristics
•
Symbol contrast
•
Print growth
•
Axial non-uniformity
•
Unused error correction
REAL
Quality parameters as classes
•
Symbol contrast
•
Print growth
•
Axial non-uniformity
•
Unused error correction
•
Overall grade
CHAR
Note
If the data to be read contains the absolute quality characteristics, remember that the value
of the "Swap" parameter (in the user interface in Connections ➜ Interfaces in PROFINET IO)
must be taken into account.