Network and system interfacing
5.2 System setup via PROFIBUS DP with ASM 456 and FB45 or Ident profile
SIMATIC MV420 / SIMATIC MV440
100
Operating Instructions, 04/2013, A5E02371045-06
5.2
System setup via PROFIBUS DP with ASM 456 and FB45 or Ident
profile
Acquisition and output of recognition values in a PROFIBUS DP environment
$60
352),%86'3
b9b'&
VXSSO\YROWDJH
$60FDEOH
&RQYH\RUV\VWHP
/LJKWEDUULHU
3&SURJUDPPLQJGHYLFHZLWK
8VHULQWHUIDFH
&RQYH\RUGLUHFWLRQ
3RZHU,256FDEOH
$XWRPDWLRQV\VWHP
2EMHFW
(WKHUQHWFDEOH
Figure 5-1
Example: System setup via PROFIBUS DP-V1 with ASM 456 and FB45 or Ident profile
System characteristics
●
Attachment to PROFIBUS is via the ASM interface of the reader and an ASM 456.
●
The connection to an automation system is established via PROFIBUS DP.
●
The reader is controlled via PROFIBUS DP-V1 by the automation system with a function
block FB45 or Ident profile.
●
The results are output to the automation system via PROFIBUS DP.
●
The power for the reader is supplied by the ASM 456 (SIMATIC MV440 only).
●
The reader is triggered either via the digital I/O or the automation system or by the
integrated autotrigger function.
●
A PC/programming device is connected via the Ethernet port to allow adjustment of the
device.