Image processing
4.2 Code verification
SIMATIC MV420 / SIMATIC MV440
56
Operating Instructions, 04/2013, A5E02371045-06
Assignment of the numeric grading of AS9132 Rev. A, and the quality levels
Grade
4
3
2
1
0
Comment
Angle of distortion (AOD)
<3.5
<7
>7
Module center offset (CO_)
C1<2%
C2<2%
C2>2% C1 is the number of modules
with a center offset less than
10% of the module size
C2 is the number of modules
with a center offset less than
20% of the module size
Module size offset (SO_)
C1<2%
C2<2%
C2>2% C1 is the number of modules
with a size offset between 70%
and 90% of the module size
C2 is the number of modules
with a size offset between 60%
and 105% of the module size
Module fill (MF_)
65%-
105%
<65% or
>105%
Reference only, 80% is ideal
Nominal module size (NMS)
Reference only, no grading
Ovality (OV_)
C1<2%
C2<2%
C2>2% C1 and C2 are the numbers of
modules with an ovality greater
than 20% of the nominal
module size
Contrast
Reference only, no grading
Summary of Contents for SIMATIC MV420
Page 2: ......
Page 418: ...Glossary SIMATIC MV420 SIMATIC MV440 416 Operating Instructions 04 2013 A5E02371045 06 ...
Page 423: ......