Process interfacing via an automation system (PLC, PC)
10.3 Control with FB 45 and Ident profile
SIMATIC MV420 / SIMATIC MV440
252
Operating Instructions, 04/2013, A5E02371045-06
Table 10- 13 Moby_CMD
Command
[hex]
Sub_
Command
[hex]
Length
[dez]
Address_
MDS [hex]
DAT_DB_number
[dez]
DAT_DB_address
[dez]
Number of the
data DB (for example
48)
Pointer to the start
word
(for example 0)
01
-
Match
string
length
+ 3
0
Pointer to the user data to be sent to the
reader.
Table 10- 14 PIB_COMMAND
Parameter
Value
CMD
0x71
OffsetBuffer
0x00
UID
0x00
Length
Match string 3
StartAddress
0x00
Table 10- 15 Command data area (FB45: Data DB, RFID standard profile: TXBUF or RXBUF)
Address
Value
Meaning
0x0000
0x03
Command identifier
"Write match string"
0x0001
0x00-0xFF
Match string length high byte
0x0002
0x00-0xFF
Match string length low byte
0x0003
1. character of the match string
...
...
n + 2
(n-1)th character of the match
string
n + 3
nth character of the match string
Summary of Contents for SIMATIC MV420
Page 2: ......
Page 418: ...Glossary SIMATIC MV420 SIMATIC MV440 416 Operating Instructions 04 2013 A5E02371045 06 ...
Page 423: ......