Connecting
7.3 Connecting components
SIMATIC MV420 / SIMATIC MV440
124
Operating Instructions, 04/2013, A5E02371045-06
Pin assignment of the Power IO RS232 cable
NOTICE
INPUT - COMMON / OUTPUT - COMMON must be connected
INPUT - COMMON / OUTPUT - COMMON must be connected before you can use the
inputs and outputs detailed below.
Table 7- 1
SIMATIC MV440
Pin
Color
Signal name
Possible values
Default
Meaning
H
Red
24 V DC
Power supply
G
Blue
0 V
Power supply
K
Violet
INPUT1
TRG
TRG
Trigger input
D
Yellow
INPUT /
OUTPUT2
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
IN_OP
Freely selectable input
or output.
L
Gray/
pink
INPUT /
OUTPUT3
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
RDY
Freely selectable input
or output.
C
Green
INPUT /
OUTPUT4
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
READ
Freely selectable input
or output.
B
Brown
INPUT /
OUTPUT5
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
N_OK
Freely selectable input
or output.
A
White
INPUT -
COMMON
Reference point 0 V or
24 V for inputs.
E
Gray
OUTPUT -
COMMON
P type inputs/outputs:
INPUT - COMMON = 0 V and
OUTPUT - COMMON = + 24 V DC
N type inputs/outputs:
INPUT - COMMON = + 24 V DC and
OUTPUT - COMMON = 0 V
Reference point 0 V or
24 V for outputs.
J
Black
STROBE
(OUTPUT)
Signal output for
connecting external
flashes
F
Pink
RS232 TXD
RS232 send line
M
Red/blue
RS232 RXD
RS232 receive line
Summary of Contents for SIMATIC MV420
Page 2: ......
Page 418: ...Glossary SIMATIC MV420 SIMATIC MV440 416 Operating Instructions 04 2013 A5E02371045 06 ...