Additional units
10.1 SIDOOR SERVICE TOOL
ATE500E
144
System Manual, 09/2017, A5E33917696-AD
10.1.2
Connection
Requirements
Connect the SIDOOR SERVICE TOOL using the supplied 9-pin D-SUB connecting cable
that has the connector types plug/socket.
Note
•
The second connecting cable supplied with the socket/socket connector types cannot be
used to connect the SIDOOR SERVICE TOOL to the ATE500E controller.
•
The cover of the controller does not have to be removed to connect the SIDOOR
SERVICE TOOL.
Procedure
CAUTION
Material damage resulting from improper use
A SIDOOR controller or the device it is connected to may be damaged by using slot X8 to
connect to fieldbus systems such as CAN, PROFIBUS or Modbus.
You should, therefore, only connect suitable SIDOOR accessories to slot X8.
①
SIDOOR Service Tool (plug-type connector)
②
D-SUB connecting cable socket-type connector
③
D-SUB connecting cable plug-type connector
④
Slot X8 on the controller (socket-type connector)
1.
Connect the socket-type connector
②
of the connecting cable to the slot (plug)
①
on the
SIDOOR SERVICE TOOL.
2.
Connect the plug-type connector
③
of the connecting cable to the slot X8 (socket)
④
on
the controller.