Configuration and programming in STEP 7
8.3 Programming SIDOOR instructions
ATD4xxW Door Controller for Industrial Applications
258
System Manual, 01/2017, A5E38080677-AB
8.3.2
"SIDOOR_SDat" data type
The "SIDOOR_SDat" data type maps the structure of the control words (slave → master).
These are identical for the process image in the case of PROFIBUS and PROFINET. The
terminal block assignments are specified in Process data (Page 285). The data type is used
for all S7 systems in SIMATIC Manager and TIA Portal.
Table 8- 2
UDT "AT_SDat"
Name
Data type
Description
See also
StatW
WORD
Status word (ZSW1)
Table A-21 Status word 1 (ZSW1)
(Page 290)
DPos
BYTE
Percentage door position
(Page 294)
DBlock
BYTE
Obstruction detection
(Page 293)
DBlcWait
BOOL
Wait obstruction mode
(Page 293)
ASDrv
BOOL
(Basic signal) AssistedDrive
(Page 296)
ASStp
BOOL
(Basic signal) ImpulseStop
(Page 296)
DMode
BYTE
Door mode
(Page 293)
DStat
BYTE
Door state
(Page 292)
ImpDrv_s
BYTE
ImpulseDrive (distance-based)
(Page 295)
ImpDrv_v
BYTE
ImpulseDrive (speed-based)
(Page 295)
DIn
BYTE
Digital inputs
Table A-35 Value selection for
TZW3, TZW4, TZW4 (Page 297)
DOut
BYTE
Digital outputs
AUTOHOTSPOT
PB
BYTE
Function button
AUTOHOTSPOT
Summary of Contents for SIDOOR ATD401W
Page 1: ......