Controllers
4.5 Relay and fieldbus interfaces
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
143
Relay control
Table 4- 20 Relay control for PROFINET module
Terminal
Assignment
Description
X100.1
X100.2
CLOSE
(closed)
The relay is additionally influenced by the sensor configuration (parameter p4600).
For more, see also section Sensors and external sensor interface module
•
Sensor function test inactive
The system's internal door state "closed" is signaled via this relay (relay con-
tact is closed). This state is not only position-dependent. Note the following
conditions:
–
The "closed" state can only be achieved with a drive order.
–
The "closed" state cannot be achieved by external pushing.
–
The "closed" state can be terminated by means of a drive order or external
pushing.
•
Sensor function test active
–
The "TestOUT" sensor function test signal is output.
X100.3
X100.4
OPEN
(open)
The system's internal door state "open" is signaled via this relay (relay contact is
closed).
This state essentially depends on the current door position.
•
The "open" state can be achieved both by means of a drive order and also by
external pushing.
•
The "open" state can be terminated by means of a drive order or external
pushing.
Connection
The wired relay connector is connected to connection X100.
Summary of Contents for SIDOOR ATD401W
Page 1: ......