Appendix
A.1 Measured variables
SENTRON PAC3100
Manual, 07/2009, A5E02385159B-01
121
Name
Abbrev.
DE + IEC
Abbrev.
EN + NAFTA
Unit
Display
Minimum apparent power b
S
L2 min
VA
b min
VA
5.2
Minimum value of the apparent power in phase conductor b
Apparent power c
VA
L3
VA
c
VA
5.0
Apparent power in phase conductor c
Maximum apparent power c
S
L3 max
VA
c max
VA
5.1
Maximum value of the apparent power in phase conductor c
Minimum apparent power c
S
L3 min
VA
c min
VA
5.2
Minimum value of the apparent power in phase conductor c
Active power a
P
L1
W
a
W
6.0
Active power in phase conductor a as import (+) or export (-)
Maximum active power a
P
L1 max
W
a max
W
6.1
Maximum value of the active power in phase conductor a
Minimum active power a
P
L1 min
W
a min
W
6.2
Minimum value of the active power in phase conductor a
Active power b
P
L2
W
b
W
6.0
Active power in phase conductor b as import (+) or export (-)
Maximum active power b
P
L2 max
W
b max
W
6.1
Maximum value of the active power in phase conductor b
Minimum active power b
P
L2 min
W
b min
W
6.2
Minimum value of the active power in phase conductor b
Active power c
P
L3
W
c
W
6.0
Active power in phase conductor c as import (+) or export (-)
Maximum active power c
P
L3 max
W
c max
W
6.1
Maximum value of the active power in phase conductor c
Minimum active power c
P
L3 min
W
c min
W
6.2
Minimum value of the active power in phase conductor c
Reactive power a (VAR1)
Q
1 L1
VAR
1 a
var
7.0
Reactive power of the fundamental in phase conductor a, referred to the load counting system,
measured according to VAR1
Maximum reactive power a (VAR1)
Q
1 L1 max
VAR
1 a max
var
7.1
Maximum reactive power of the fundamental in phase conductor a referred to the load counting
system, measured according to VAR1
Minimum reactive power a (VAR1)
Q
1 L1 min
VAR
1 a min
var
7.2
Minimum reactive power of the fundamental in phase conductor a, referred to the load counting
system, measured according to VAR1
Reactive power b (VAR1)
Q
1 L2
VAR
1 b
var
7.0
Reactive power of the fundamental in phase conductor b, referred to the load counting system,
measured according to VAR1
Maximum reactive power b (VAR1)
Q
1 L2 max
VAR
1 b max
var
7.1
Maximum reactive power of the fundamental in phase conductor b, referred to the load counting
system, measured according to VAR1
Summary of Contents for SENTRON PAC3100
Page 10: ...Table of contents SENTRON PAC3100 10 Manual 07 2009 A5E02385159B 01 ...
Page 38: ...Mounting 5 3 Deinstallation SENTRON PAC3100 38 Manual 07 2009 A5E02385159B 01 ...
Page 104: ...Service and maintenance 10 5 Disposal SENTRON PAC3100 104 Manual 07 2009 A5E02385159B 01 ...
Page 118: ...Dimensional drawings SENTRON PAC3100 118 Manual 07 2009 A5E02385159B 01 ...
Page 142: ...Appendix A 3 Correction sheet SENTRON PAC3100 142 Manual 07 2009 A5E02385159B 01 ...
Page 146: ...List of abbreviations C 1 Abbreviations SENTRON PAC3100 146 Manual 07 2009 A5E02385159B 01 ...
Page 148: ...Glossary SENTRON PAC3100 148 Manual 07 2009 A5E02385159B 01 ...
Page 152: ...Index SENTRON PAC3100 Manual 07 2009 A5E02385159B 01 152 ...