Technical data
8.1 Technical specifications of the SCALANCE XR524-8C
SCALANCE XR-500
84
Operating Instructions, 05/2017, A5E03275845-11
Technical specifications
Frequency range
47 Hz to 63 Hz
Fusing
3.15 A / 250 V
Current consumption at 100 VAC
0.6 A
Current consumption at 240 VAC
0.37 A
Effective power loss
24 W
Properties
Not implemented redundantly
2 x 100 to 240 VAC
Design
IEC plug C14 with switch,
2-pin
Rated voltage
100 V to 240 V AC
Voltage range
90 to 264 VAC
Frequency
60 Hz to 50 Hz
Frequency range
47 Hz to 63 Hz
Fusing
3.15 A / 250 V
Current consumption at 100 VAC
0.6 A
Current consumption at 240 VAC
0.37 A
Effective power loss
24 W
Properties
Implemented redundantly
Permitted ambient conditions
Ambient temperature
For devices with 24 VDC
2)
When operating without pluggable
transceiver of the types LH, LH+, ELH
or ELH200
up to 2000 m
-40
℃ to +70 ℃
When operating as of 2000 m
The maximum ambient temperature is
reduced by 5°C
During storage
-
40 ℃ to +85 ℃
During transportation
-
40 ℃ to +85 ℃
Ambient temperature
for devices with 100 to 240 VAC
2)
When operating without pluggable
transceiver of the types LH, LH+, ELH
or ELH200
up to 2000 m
-
25 ℃ to +60 ℃
When operating as of 2000 m
The maximum ambient temperature is
reduced by 5°C
During storage
-
40 ℃ to +85 ℃
During transportation
-
40 ℃ to +85 ℃
Relative humidity
During operatio
n at 25 ℃
≤ 95%, no condensation
Design, dimensions and weight
Weight
2 x 24 VDC
3.8 kg
1 x 100 to 240 VAC
4.2 kg
2 x 100 to 240 VAC
4.5 kg
Degree of protection
IP20
Dimensions without brackets for
19" rack mounting (W x H x D)
446 x 44 x 305 mm (1 height unit)