Description
The page contains the following boxes:
● EtherNet/IP Device Diagnostics
Shows whether EtherNet/IP is enabled ("On") or disabled ("Off").
● EtherNet/IP Device Diagnostics for next boot
Set whether EtherNet/IP will be enabled ("On") or disabled ("Off") after the next device
restart.
Note
EtherNet/IP and PROFINET
When EtherNet/IP is turned on, PROFINET is turned off. The switchover from EtherNet/IP
and PROFINET has no effect on DCP.
Note
PROFINET AR Status
If a PROFINET connection is established; in other words the PROFINET AR status is
"Online", you cannot enable EtherNet/IP.
6.5.18
PLUG
6.5.18.1
Configuration
NOTICE
Do not remove or insert the PLUG during operation.
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether a PLUG is inserted at one second intervals. If it is detected that the
PLUG was removed, there is a restart.
If a valid PLUG was inserted in the device, the device changes to a defined error state
following the restart. With SCALANCE W, the available wireless interfaces are deactivated in
this case.
If the device was configured at one time with a PLUG, the device can no longer be used
without this PLUG. To be able to use the device again, reset the device to the factory settings.
Configuring with Web Based Management
6.5 "System" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
210