Type
Description
Save
Download
WLANAuthlog
File with entries from the WLAN Authentication Log (information on success‐
ful or failed authentication attempts)
X
--
WLANCert
(only in client
mode)
User certificate. You can specify a password for the user certificate on the
WBM page "Load&Save > Password".
Maximum file size: 8192 bits
X
X
WLANServerCert
(only in client
mode)
Server certificate
Maximum file size: 8192 bits
X
X
WLANSigRec
(only in client
mode)
The zip file contains the following:
● csv file with the measured values of the signal recorder
● pdf file with the measured values and an additional graphic
representation of the measured values.
You will find information about the measured values and their graphic repre‐
sentation in the section "Signal recorder (Page 242)".
X
--
6.5.7.2
HTTP
Loading and saving data via HTTP
The WBM allows you to store device data in an external file on your client PC or to load such
data from an external file from the PC to the devices. This means, for example, that you can also
load new firmware from a file located on your client PC.
Note
This WBM page is available both for connections using HTTP and for connections using
HTTPS.
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens can
be downloaded to the device.
Configuration files
Note
Configuration files and trial mode/Automatic Save mode
In Automatic Save mode, the data is saved automatically before the configuration files
(ConfigPack and Config) are transferred.
In Trial mode, although the changes are adopted, they are not saved in the configuration files
(ConfigPack and Config). Use the "Write Startup Config" button on the "System >
Configuration" WBM page to save changes in the configuration files.
CLI script file
Configuring with Web Based Management
6.5 "System" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03