Revision Date: 3/13/2019
BMC Contacts ............................................................................................................................... 1
Scanner Operation ........................................................................................................................ 2
How to do a “Standby” Reboot ............................................................................... 2
How to Turn Off the MRI Scanner/Computer (Full Shutdown)............................. 3
How to Turn on the MRI Scanner/Computer ......................................................... 4
MR Scanner Error Save Log ................................................................................... 4
How to Check the System Manager........................................................................ 5
How to Restart the Coldhead .................................................................................. 6
How to Reboot the Chiller ...................................................................................... 7
Export and Save Raw Data Files (.RDA and Raw) ................................................................... 8
How to Map a Non-Dicom Network Folder on the Scanner Console .................... 8
How to Create a Spectroscopy .RDA File .............................................................. 8
How to Transfer Raw Data Using TWIX Software ................................................ 9
Prisma Cleanup Procedures....................................................................................................... 10
General Cleanup Guidelines ................................................................................. 10
Squeeze Ball/Button Alarm ........................................................................................................ 11
What to do when the Squeeze Ball/Button Alarm Goes Off ................................ 11
Reset the Table ...................................................................................................... 11
How to Run the Daily Stability Warmup ................................................................................. 12
Setting up the Phantom ......................................................................................... 12
Register Phantom .................................................................................................. 12
Running Scans ...................................................................................................... 12
Registration Pictures ............................................................................................. 13
How to Run the ABCD Phantom QA ........................................................................................ 14
Setting up the Phantom ......................................................................................... 14
Register the Phantom ............................................................................................ 15
Running Scans ...................................................................................................... 16
Registration Pictures ............................................................................................. 17
How to Trigger Test Stimuli/Tasks ........................................................................................... 18
Setting up the Phantom ......................................................................................... 18
Register Phantom .................................................................................................. 18
Running Scans ...................................................................................................... 18
Registration Pictures ............................................................................................. 19
Coil Warnings - Protocol Was Fixed ......................................................................................... 20
Main Reasons for Coil Warnings .......................................................................... 20
Anterior or Posterior Protocol Fixed Warning Messages ..................................... 20
Resolution ............................................................................................................. 20
Wrong Coil Protocol Fixed Warning Messages ................................................... 20
Prisma VE11C Software Bugs ................................................................................................... 22
AutoAlign Re-Run Failure .................................................................................... 22
AP/PA Copy Reference Issue ............................................................................... 22
Reconstruction Error (aka Blob error) .................................................................. 23
Prisma VE11C Scanner Warnings/Messages/Errors .............................................................. 24
Adjustment Measurement Was Aborted ............................................................... 24
Gradient Power Amplifier Warning ...................................................................... 24
Participant Registration Errors .............................................................................. 25