Configuration
43
Siemens Building Technologies
Fire Safety & Security Products
04.2006
10.5.7 Service
configuration
1.
Open the unit’s home page. See Section 7.4 Accessing the unit’s home page.
2.
In the
Configuration
menu, select the menu option
Camera
and the
Service
suboption.
Î
The
Service
dialog will appear:
Fig. 13
Service
3.
Enter the desired settings in this dialog.
IMPORTANT
Cover the lens before using the pixel error compensation (blemish)
function.
Failing to do so may cause errors with the IP camera.
Blemish
If the lens is covered a test can be made for defective pixels.
Click the
Detect
button.
The presence of defective pixels will be checked and corresponding
compensation configured.
CAUTION
The factory defaults function will reset the IP camera to its
configuration on delivery.
Factory defaults
Click the
Restore
button.
Î
The following confirmation message will be displayed:
Are you sure you want to restore the factory settings of the IP
camera?
Back focus
The following options for flange focal length (back focus) are available:
z
ON
The lens aperture is opened completely and the shutter speed set
temporarily to AUTO to facilitate configuration.
z
OFF
The function is deactivated.