Configuration
39
Siemens Building Technologies
Fire Safety & Security Products
04.2006
10.5.3 Setting the synchronization
1.
Open the unit’s home page. See Section 7.4 Accessing the unit’s home page.
2.
In the
Configuration
menu, select the menu option
Camera
and the
Synchronization
suboption.
Î
The
Synchronization
dialog will appear:
Fig. 9
Synchronization settings
3.
Enter the desired settings in this dialog.
Operating mode
The following options are available:
Prerequisite:
The LL mode is only available for camera models with AC power
supply.
z
INT
The IP camera is in the internal SYNC mode (quartz).
z
INT
The IP camera is in line lock mode.
VPhase (0 to 300°)
Select a phase angle from 0 to 300° for the
LL
operating mode. The
default setting is 0°.
NOTE
With DC operation SYNC automatically selects INT mode even if
LL has been set.
4.
Click
Save
.