2.5.1 Offline Menu
The Offline menu provides access to two other menus: New Configuration and Saved Configuration.
These two configuration menus can be used without connecting to a HART-compatible device, but it is
not possible to send saved data to a device if no device is connected.
In the Main menu, press “1 Offline” on the keypad or the RIGHT ARROW/SELECT key to access the
Offline menu. The complete menu tree for the Offline Menu is shown in Figure 2-4.
Main Menu
1 New
1 Moore Products
List of Models
Field Device From a Blank
1 Offline
Configuration
2 Rosemount
Revision
Template
3 Siemens
1 Mark all
2
Unmark
all
3 Edit individually >
4 Save as...
1 Location
2
Name
3
Data
type
2 Save
1 Module Contents
List of
1 Edit
1 Mark all
Configuration
2 Data Pack
Configurations
2 Unmark all
Contents
3 Edit individually >
3 PC
4 Save as...
1 Location
2 Copy to...
2 Name
3 Send
3 Data type
4
5
Delete
6
Rename
7
Compare
2 Online
3 Frequency
Device
Note: > = See Table 2-3 for additional menu
options
4 Utility
FIGURE 2-4 Offline Menu Map
TABLE 2-3 Offline Menu Map Continued, “Edit individually” Options
1
Tag (type)
2
Alarm URV (type)
Flange type (select)
Extension length (select)
Descriptor (type)
Pres xfer function (select)
Flange material (select)
Electrical connection (select)
Date (type)
Pressure damp (type)
O ring material (select)
Local keys ctrl mod (select)
Pressure unit (select)
AO alarm type (select)
Process flange bolt (select)
Bargraph (select)
Pressure LRV (type)
Alarm LRV (type)
DrainVent / plug mat (select)
Unit tracking (select)
Pressure URV (type)
Alarm URV (type)
DrainVent / plug POS (select) Local display unit (select)
Pres transfer function (select)
Upper AO limit (type)
RS type (select)
Measuring speed (select)
Pressure damp (type)
Lower AO limit (type)
RS isoltr material (select)
Final assembly num (type)
AO alarm type (select)
Meter type (select)
RS fill fluid (select)
Alarm LRV (type)
Process connection (select)
Num remote seal (select)
Notes:
1. Menu sequence is read top to bottom, left to right.
2. (type) = type a value or text; (select) = select from the list offered.
Summary of Contents for 7MF4033 series
Page 48: ...Model 275 Universal Hart Communicator UMSITRPDS3 1 November 2010 2 26 ...
Page 86: ...Installation UMSITRPDS3 1 November 2010 4 34 ...
Page 152: ...Calibration and Maintenance UMSITRPSD3 1 November 2010 7 20 ...
Page 158: ...Circuit Description UMSITRPDS3 1 November 2010 8 6 ...
Page 197: ......
Page 198: ......
Page 200: ...Model Designations and Specifications UMSITRPDS3 1 November 2010 9 42 ...
Page 204: ...Glossary UMSITRPDS3 1 November 2010 10 4 ...
Page 208: ...Appendix A Online Configuration Map UMSITRPDS3 1 11 4 November 2010 ...
Page 216: ...Appendix C Elevation and Suppression Correction UMSITRPDS3 1 13 4 November 2010 ...