UMSITRPDS3-1
Calibration And Maintenance
November 2010
7-1
7.0 CALIBRATION AND MAINTENANCE
This section discusses calibration, preventive maintenance, troubleshooting, assembly replacement,
software compatibility, and return shipments.
The Calibration section contains a brief discussion of the cause of position induced zero shift and it
provides references to needed calibration procedures. The Preventive Maintenance portion has procedures
that are employed to protect the reliability of the transmitter. Should a malfunction occur, procedures in
the Troubleshooting section can help minimize downtime. The Assembly Removal and Replacement
section provides step-by-step assembly replacement procedures. Later sections discuss recommended
spare and replacement parts, software compatibility, and return shipments.
WARNING
Explosion can cause death or serious injury.
In a Division 1 area, where an explosion-proof rating is
required, remove power from the transmitter before
removing either enclosure cap.
Tools and Equipment Required
The procedures in this section can require the following equipment. See the Note below.
•
Model 275 HART Communicator or Model 375 Field Communicator
•
Laboratory grade digital multimeter (DMM) for troubleshooting and calibrating the 4 to 20 mA
output signal; a meter certified for use in intrinsically safe circuits must be used in an intrinsically
safe installation
Voltmeter Section
Accuracy ±0.01% of reading
Resolution 1.0 mV
Input impedance 10 M
Ω
Ammeter Section
Accuracy ±0.1% of reading
Resolution ±1
μ
A
Shunt resistance 15
Ω
or less
•
24 Vdc power supply; for bench setup
•
Resistor 250
Ω
±1%, carbon, ¼ watt; for bench setup
•
Set of Phillips and flat-blade screwdrivers
•
Set of open-end or box-end wrenches
•
Larger tweezers, 4" to 6"
Note: If using a Model 375 Field Communicator, see the inside
of the front cover of this manual.
Summary of Contents for 7MF4033 series
Page 48: ...Model 275 Universal Hart Communicator UMSITRPDS3 1 November 2010 2 26 ...
Page 86: ...Installation UMSITRPDS3 1 November 2010 4 34 ...
Page 152: ...Calibration and Maintenance UMSITRPSD3 1 November 2010 7 20 ...
Page 158: ...Circuit Description UMSITRPDS3 1 November 2010 8 6 ...
Page 197: ......
Page 198: ......
Page 200: ...Model Designations and Specifications UMSITRPDS3 1 November 2010 9 42 ...
Page 204: ...Glossary UMSITRPDS3 1 November 2010 10 4 ...
Page 208: ...Appendix A Online Configuration Map UMSITRPDS3 1 11 4 November 2010 ...
Page 216: ...Appendix C Elevation and Suppression Correction UMSITRPDS3 1 13 4 November 2010 ...