Online Configuration Map for
Siemens SITRANS P DSIII Pressure Transmitter with
Model 375 Field Communicator
5 Config Inp/Outp,
2 Input, Continued
3 Meas Switch/Mapper
1 measurement
Continued
2 PV is
3 SV is
4 TV is
5 QV is
6 (measurement) config
1 Input scaling
1 Pres abs/rel
e.g. Level
2 Pressure unit
3 Input LRV
4 Input URV
2 Level scaling
1 Level unit
e.g. Level scaling
2 Level LRV
3 Level URV
3 Volume scaling
1 Volume unit
2 Vol LRV
3 Vol URV
2 Density unit
3 Density
3 Mass unit
6 (measurement) config
1 Input scaling
1 Pres abs/rel
e.g. Flow
2 Pressure unit
3 Input LRV
4 Input URV
2 Flow scaling
1 Vol flow unit
2 Vol flow LRV
3 Vol flow URV
2 Density unit
3 Density
3 Mass flow unit
6 (measurement) config
1 Input scaling
1 Pres abs/rel
e.g. Customer
2 Pressure unit
3 Input LRV
4 Input URV
3 Customer scaling
1 Cust unit (5 Ch)
2 Cust LRV
3 Cust URV
7 User linearization
1 Special Curve status -->
only if meas not pres
if Level, Flow or Customer
2 No curve points
this is valid - otherwise not
3 Setup special char --> M
4 Display special char --> M
4 Meas.Limits & Span
1 Module range
2 Active Device Variables
1 Pressure
1 Pressure unit
2 Pres USL
3 Pres LSL
4 min span
5 Trimpoint sum
2 Sens-Temp
1 Sens-Temp unit
2 Sens-Temp USL
3 Sens-Temp LSL
4 Sens-Temp min.span
3 Electr-Temp
1 Electr-Temp unit
2 Electr-Temp USL
3 Electr-Temp LSL
4 Electr-Temp min.span
4 Untrimmed Pres
1 Untrimmed Pres unit
2 Untrimmed Pres USL
3 Untrimmed Pres LSL
4 Untr Pres min.span
additional if measurement
5 Level
1 Level unit
is mapped to level
2 Level USL
3 Level LSL
4 Level min.span
additional if measurement
6 Volume
1 Volume unit
is mapped to level
2 Volume USL
3 Volume LSL
4 Volume min.span
additional if measurement
7 Mass
1 Mass unit
is mapped to level
2 Mass USL
3 Mass LSL
4 Mass min.span
additional if measurement
5 Vol-Flow
1 Vol-Flow unit
is mapped to flow
2 Vol-Flow USL
3 Vol-Flow LSL
4 Vol-Flow min.span
additional if measurement
6 Mass-Flow
1 Mass-Flow unit
Continued on pg 3
is mapped to flow
2 Mass-Flow USL
3 Mass-Flow LSL
4 Mass-Flow min.span
additional if measurement
5 Customer
1 (PV) unit
is mapped to customer
2 Customer USL
3 Customer LSL
4 Customer min. span
Page 2
Summary of Contents for 7MF4033 series
Page 48: ...Model 275 Universal Hart Communicator UMSITRPDS3 1 November 2010 2 26 ...
Page 86: ...Installation UMSITRPDS3 1 November 2010 4 34 ...
Page 152: ...Calibration and Maintenance UMSITRPSD3 1 November 2010 7 20 ...
Page 158: ...Circuit Description UMSITRPDS3 1 November 2010 8 6 ...
Page 197: ......
Page 198: ......
Page 200: ...Model Designations and Specifications UMSITRPDS3 1 November 2010 9 42 ...
Page 204: ...Glossary UMSITRPDS3 1 November 2010 10 4 ...
Page 208: ...Appendix A Online Configuration Map UMSITRPDS3 1 11 4 November 2010 ...
Page 216: ...Appendix C Elevation and Suppression Correction UMSITRPDS3 1 13 4 November 2010 ...