610.43 600.21
Siemens AG
Fig. 2 Lift and transport with a lifting beam
Observe the transport regulations applying in the country/countries concerned.
Store in a dry, low-dust and low-vibration place (v
eff
< 0.2 mms
-1
).
4.2
Installation
Fig. 3 Types of construction
- Take note of and observe the information on the rating plate and warning and informative
notices on the motor.
- Observe the permitted transverse and axial forces (see project planning instructions).
Axial forces are not permitted on motors with an integrated or fitted brake.
- A minimum transverse force is required for a reinforced bearing arrangement. This
bearing arrangement is not suitable for a coupling drive, this requires a simple bearing
arrangement.
- Check for compliance with the conditions (e.g. temperature, site altitude) at the assembly
site (see 3.2).
- It is forbidden to use them in areas at risk of explosion.
- Remove all anti-corrosion agents from the shaft end (use commercially available
solvent).
- After a lengthy period of storage, check the insulation resistance (dry the winding if the
values are < 1 k
Ω
per volt of rated voltage).
- Tighten the flanges equally, avoid distortions when tightening the fixing screws. Tighten
diagonally! Use hexagon socket head cap screws, strength class at least 8.8.
IM V1 / IM V15
IM B3 / IM B5 / IM B35
IM V 3 / IM V36