IV351 Rev04
Ausstellungsdatum 2015-04-21
Seite 248 von 277 + FR
10.
Erweiterte Einstellungen
Im Anschluss finden Sie die Beschreibung des Konfigurationsmenüs der Parameter des
Wechselrichters für die in der Norm
VDE-AR-N 4105
vorgesehenen Netzdienstleistungen.
Reactive Power Mode
Const. PF
Const. Q
Curve PF(P)
Curve Q(U)
Reactive Power Mode
Reactive Power Mode
Const. PF
Const. Q
Curve PF(P)
Curve Q(U)
Reactive Power Mode
Const. PF
Const. Q
Curve PF(P)
Curve Q(U)
Reactive Power Mode
Const. PF
Const. Q
Curve PF(P)
Curve Q(U)
Reactive Power Mode
Const. PF
Const. Q
Curve PF(P)
Curve Q(U)
Const. PF
Const. Q
Curve PF(P)
Curve Q(U)
Reactive Power Mode
<Off>
Off
Const. Q
<+1000VAR>
+1000VAR
Const. PF
<+1.00pf >
+1.00pf
Curve Q(U)
Type: A
P lock-in: 20% Pn
P lock-out: 5% Pn
Node 1: 90% +43.6% Q/S
Node 2: 92% +0% Q/S
Node 3: 108% +0% Q/S
Node 4: 110% -43.6% Q/S
Curve PF(P)
V lock-in: 241.5 V
V lock-out: 230.0 V
Node 1: 20% +1.00pf
Node 2: 40% +1.00pf
Node 3: 50% +1.00pf
Node 4: 90% -0.90pf
Off/Const. PF/Const. Q/Curve
PF(P)/Curve Q(U)
10k model: -4358~+4358VAR
15k model: -6537~+6537VAR
20k model: -8717~+8717VAR
-0.90~+0.90pf
Type: A/B
P lock-in: 10~100%
P lock-out: 5%
Node (X-axis): 80~120%
Node (Y-axis): -43.6~+43.6%
V lock-in: 230.0~253.0V
V lock-out: 207.0~230.0V
Node (X-axis): 0~100%
Node (Y-axis): -0.90~+0.90pf
OK
OK
OK
OK
OK
Reactive Power Func.
Mode:Off
Value:N/A
Press OK over 5s to
change the setting
Reactive Power Func.
Mode:Const. Q
Value:+1000VAR
Press OK over 5s to
change the setting
Reactive Power Func.
Mode:Const. PF
Value:+0.90pf
Press OK over 5s to
change the setting
Reactive Power Func.
Mode:Curve Q(U) Type: A
Value: 1. 90% +43.6% Q/S
2. 92% +0% Q/S
3. 108% +0% Q/S
4. 110% -43.6% Q/S
P lock-in: 20% Pn
P lock-out: 5% Pn
Reactive Power Func.
Mode:Curve PF(P)
Value:1. 20% +1.00pf
2. 40% +1.00pf
3. 50% +1.00pf
4. 100% -0.90pf
V lock-in: 241.5 V
V lock-out: 230.0 V
Password
• •
: Select char
: Delete : Next
1
ź
ź
ź
ź
Incorrect password
Press any button
A
241.5
Press OK button
If password is correct
(Password: 14914)
Reactive Power Func.
Mode:Off
Value:N/A
Press OK over 5s to
change the setting
Press OK button
over 5 seconds
Five conditions on this screen
Die Bezugsnorm VDE-AR-N
4105 sieht keine Einstellung
der Parameter V lock-in/out
und P lock-in/out vor.
Diese beiden Parameter
beziehen sich nur auf die Norm
CEI-021
.
Summary of Contents for SOLEIL 3F-TL10K
Page 89: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 89 di 277 FR 17 2 Diagramma efficienza ...
Page 90: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 90 di 277 FR ...
Page 180: ...IV351 Rev04 Date Issue 2015 04 21 Page 180 di 277 FR 17 2 Efficiency Chart ...
Page 181: ...IV351 Rev04 Date Issue 2015 04 21 Page 181 di 277 FR ...
Page 251: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 251 von 277 FR ...
Page 275: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 275 von 277 FR 17 2 Wirkungsgradkurve ...
Page 276: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 276 von 277 FR ...