IV351 Rev04
Date Issue 2015-04-21
Page 167 di 277 + FR
Exchange procedures of fan module for the SOLEIL 3F-TL15K model:
(8)
Disconnect the AC power and the DC power of PV inverter.
(9)
Unfasten all the screws of fan module as figure indicated below:
(10)
Take off the fan module and disconnect its cable adapter as figure indicated below:
(11)
Clean fan with damp cloth or soft brush tenderly if needed.
(12)
If fan module is damaged or malfunctioned permanently, please make a
replacement by a new fan module.
(13)
Assemble the fan module in the reverse order of above procedures.
(14)
Check Inverter resumes normal operation after restart.