background image

 

 

IV351 Rev04   
Date Issue: 2015-04-21  

 

 

 

 

 

                    Pagina 39 di 277 + FR 

Illustrazione della sequenza visualizzata del registratore dati 

 

Summary of Contents for SOLEIL 3F-TL10K

Page 1: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 1 di 277 FR Inverter Soleil per collegamento in rete SOLEIL 3F TL10K DE IT ES UK SOLEIL 3F TL15K DE IT ES UK SOLEIL 3F TL20K DE IT ES UK Manuale di istruzione ...

Page 2: ... INVERTER FV 31 6 1 USO DEL SEZIONATORE DC 31 6 2 INIZIALIZZAZIONE PER L IMPOSTAZIONE DEL TIPO DI NORMATIVA 31 6 3 MODALITÀ OPERATIVE 32 6 4 USO DEL DISPLAY LCD E DEL REGISTRATORE DATI 35 7 SERVIZI DI RETE 40 7 1 POTENZAATTIVA 40 7 1 1 RIDUZIONE DELLA POTENZAATTIVA 40 7 2 POTENZA REATTIVA 41 8 STATO DI FUNZIONAMENTO DELL INVERTER 45 9 COMUNICAZIONI 53 9 1 USB SU INVERTER 53 9 2 SLOT COMUNICAZIONI ...

Page 3: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 3 di 277 FR 15 SMALTIMENTO 86 16 INFORMAZIONI DI CONTATTO 87 17 DIAGRAMMI EFFICIENZA 88 17 1 GRAFICI DI CARICO 88 17 2 DIAGRAMMA EFFICIENZA 89 ...

Page 4: ... FV è un prodotto altamente affidabile grazie al design innovativo e al perfetto controllo qualitativo L inverter viene utilizzato negli impianti fotovoltaici a elevato carico collegati alla rete In caso di problemi durante l installazione o durante il funzionamento dell unità consultare il manuale prima di contattare il rivenditore o fornitore locale Le istruzioni contenute nel presente manuale c...

Page 5: ...uito DC potrebbero ancora contenere carica elettrica residua Dopo aver scollegato l alimentazione e prima di lavorare sul dispositivo attendere almeno 1 minuto Solo per rete elettrica pubblica L inverter FV è progettato per fornire alimentazione AC direttamente alla rete dell azienda di servizio pubblico Non collegare l uscita AC del dispositivo ad apparecchiature AC private Superfici calde Anche ...

Page 6: ...ili z utilizzo di materiali non appropriati per la pulizia del prodotto come benzina alcool ecc z installazione ed utilizzo di cavi elettrici non appropriati z forza maggiore per es sovratensioni fulmini calamità naturali incendi inondazioni terremoti atti di guerra sommosse atti di vandalismo etc z qualora i materiali vengano installati in condizioni diverse da quelle prescritte z Applicazioni ch...

Page 7: ...giuntore AC Interfaccia tra la rete elettrica pubblica e l inverter FV per l installazione dei dispositivi di protezione richiesti dalle normative sulla sicurezza ad esempio commutatori AC interruttori AC fusibili e terminali di connessione Per garantire la conformità ai codici e alle normative locali in materia di sicurezza la configurazione dell impianto di produzione dell energia deve essere pr...

Page 8: ...di rete FV SIEL Soleil converte la corrente continua DC generata dai moduli FV in corrente alternata AC compatibile con la rete locale di distribuzione dell elettricità denominata anche Rete pubblica Modello Aspetto Dimensioni mm SOLEIL 3F TL10K 548 565 275 SOLEIL 3F TL15K 548 565 275 SOLEIL 3F TL20K 548 565 275 ...

Page 9: ...allato a scopo di gestione e manutenzione o per rivolgersi all assistenza Numero di modello e numero di serie Sul lato sinistro dell inverter è presente la targa dati dello stesso La targa riporta Tipo Marca Denominazione modello Specifiche tecniche e Numero di serie dell inverter In caso di difficoltà durante l installazione o il funzionamento annotare il numero di serie prima di rivolgersi al ri...

Page 10: ...a di comunicazione RS485 standard Gli utenti potranno collegarsi all inverter e monitorarne lo stato e il funzionamento in tempo reale da remoto 5 Dissipatore di calore Dispositivo utilizzato per dissipare il calore nell ambiente circostante 6 Interfaccia USB Collega questa porta direttamente al PC tramite un cavo USB per consentire all utente di comunicare con l inverter tramite uno specifico sof...

Page 11: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 11 di 277 FR SOLEIL 3F TL10K DE IT ES UK SOLEIL 3F TL15K DE IT ES UK SOLEIL 3F TL20K DE IT ES UK ...

Page 12: ...e dati 5 anni Supporto di memorizzazione Scheda SD 2 GB fino a 32 GB Scarico Dati Tramite USB tipo B Caratteristiche del registratore grafico dati Retroilluminazionein diversi colori La retroilluminazione dell LCD viene modificata in funzione al relativo stato I tre colori della retroilluminazione indicano z Verde Avvio Stato normale z Rosso Malfunzionamento Questo stato indica che l inverter si è...

Page 13: ... immessa in rete Si consiglia di non utilizzare i dati per il controllo o il collaudo dell impianto Di solito la precisione è circa il 2 In tutti gli intervalli di funzionamento la deviazione della precisione è di circa il 5 La tolleranza di lettura può variare dal 2 al 5 in funzione delle condizioni di funzionamento Nel caso fosse necessario una misurazione precisa dello stato del sistema install...

Page 14: ...oto supplementare come un registratore dati esterno Maximum Power Point Tracking MPPT Un inverter FV deve riuscire a convertire il massimo di potenza da ciascun pannello FV Grazie alla sua progettazione all avanguardia questo inverter FV può estrarre la massima potenza dal pannello FV in qualsiasi condizione Quando la potenza visualizzata sull LCD non cambia in maniera significativa l inverter sta...

Page 15: ...del dispositivo all assistenza Di seguito viene fornito il contenuto della Scatola Accessori 3 Articolo Quantità Descrizione articolo Figura Manuale d uso 1 Manuale di installazione e uso Coperchio AC 1 Coperchio superiore utilizzato per il Morsetto AC Estrattore connettore DC 1 Strumento per scollegare il connettore DC Isolante in gomma 1 Accessori per il collegamento dei fili AC Ancoraggio in ny...

Page 16: ...rfici infiammabili di legno Scelta del luogo di installazione È possibile installare e mettere in funzionamento l inverter di rete FV SIEL in ambienti con temperatura fino a 60qC Tuttavia per un funzionamento ottimale si consiglia di installare l inverter ove la temperatura ambiente è tra 0 e 45qC Avvertenza Non esporre l inverter FV alla luce solare diretta La luce solare diretta aumenta la tempe...

Page 17: ... disporre di almeno di 30 cm al di sopra e 90 cm al di sotto l inverter 3 Per facilitare la manutenzione montare gli inverter ad almeno 30 cm di distanza l uno dall altro Nota Non impilare gli inverter o montarli sopra altre fonti di calore salvo non sia disponibile altra alternativa In tal caso lasciare uno spazio minimo di almeno 100 cm tra le varie unità per consentire un adeguata ventilazione ...

Page 18: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 18 di 277 FR Staffa di montaggio Note Il diametro della vite di sicurezza è 10 mm2 ...

Page 19: ...l inverter nella posizione di installazione utilizzando un adeguato strumento di sollevamento dopo aver montato sull inverter stesso i supporti come illustrato Sollevamento dell inverter nella posizione di installazione opzionale Note Utilizzare un corretto strumento di sollevamento ...

Page 20: ...e 2015 04 21 Pagina 20 di 277 FR 6 Montare l inverter sulla staffa come da illustrazione Montaggio dell inverter FV a parete 7 Verificare che il dispositivo sia correttamente fissato alla staffa con la corretta inclinazione ...

Page 21: ...rica 3 Trovare i cavi di uscita AC del diametro consigliato come indicato dalla tabella in basso L1ᇬL2ᇬL3ᇬNᇬPE1 devono utilizzare cavi del diametro minimo indicato nella tabella seguente Modello SOLEIL 3F TL10K SOLEIL 3F TL15K SOLEIL 3F TL20K Potenza W 10000 15000 20000 Max corrente AC 16 A 24 A 30A Diametro max cavo AC 10 AWG 8 AWG 8 AWG Nota non utilizzare cavi con perdita superiore all 1 La sez...

Page 22: ...PE devono essere saldamente connessi al morsetto AC dell inverter FV prima di accendere l alimentazione AC Quando è necessario scollegare il servizio AC dall inverter spegnere prima l alimentazione DC dell inverter Quindi scollegare l alimentazione AC Fase L1ᇬ Fase L2ᇬFase L3 e Fase N dell inverter FV allo stesso tempo per proteggere l inverter stesso In caso di mancata osservanza di quanto sopra ...

Page 23: ...icare che l inverter sia montato correttamente provando a sollevarlo leggermente dalla parte inferiore e ruotandolo L inverter dovrebbe restare attaccato saldamente Dopo il montaggio verificare la selezione di una posizione di installazione che consenta la chiara visualizzazione del display di stato che la parete di montaggio selezionata sia robusta in modo da impedire vibrazioni durante il funzio...

Page 24: ...rsetti per il collegamento dell inverter alla Rete pubblica L unità di giunzione AC deve essere progettata da un tecnico qualificato ed essere conforme alle normative locali di sicurezza Modello SOLEIL 3F TL10K SOLEIL 3F TL15K SOLEIL 3F TL20K Max corrente AC 16A 24A 30A Protezione nominale esterna dalle sovracorrenti 20A 25A 35A Attenzione Selezionare un dispositivo di protezione dalle sovracorren...

Page 25: ...V 24A 2 SOLEIL 3F TL15K ู1000V 30A 2 SOLEIL 3F TL20K ู1000V 34 5A 2 Attenzione selezionare una spina cavo connettore DC esterno che sopporti una corrente nominale maggiore della corrente DC massima dell inverter Attenzione selezionare pannelli FV con corrente di corto circuito minore della corrente DC massima dell inverter 9Collegare sempre il polo positivo dei moduli FV al polo DC positivo dell i...

Page 26: ...ecifico con polo negativo collegato a terra No Nota farsi consigliare il tipo di modulo FV dal proprio rivenditore Requisiti del modulo FV Per collegarsi all ingresso DC di un unico inverter le stringhe connesse devono essere composte da moduli dello stesso tipo Non condividere la connessione DC in ingresso con altri inverter Il numero l orientamento e l inclinazione dei pannelli può variare in fu...

Page 27: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 27 di 277 FR La tabella seguente elenca tali coppie di connettori MultiContact Amphenol PV KST4 6I Maschio Helios H4 Maschio PV KBT4 6I Femmina Helios H4 Femmina ...

Page 28: ...ustrano le modalità di disconnessione del connettore DC MC Amphenol utilizzando l estrattore presente nella scatola degli accessori fornita con l inverter 1 Inserire lo strumento nel connettore per serrare le clip come da figura seguente 2 Dopo aver serrato le clip tirare il connettore leggermente verso il basso per smontare il cavo DC ...

Page 29: ...nente 5 8 Elenco di controllo post installazione 9 Se il pannello viene esposto a un irradiazione sufficiente sarà presente alta tensione I morsetti esposti del pannello FV sono sotto tensione e possono causare scosse elettriche Evitare il contatto con tali componenti del dispositivo 9 Dopo aver collegato il pannello FV all inverter la tensione di uscita è maggiore di 260VDC Se la rete AC non è co...

Page 30: ...scollegato l alimentazione AC quindi aprire il sezionatore DC se presente e per ultimo scollegare i cavi DC Avvertenza Verificare che la tensione AC non sia mai superiore alle specifiche del prodotto Attenzione Prima di collegare la potenza DC all inverter utilizzare un multimetro per verificare che la polarità di ogni coppia di ingresso DC sia corretta L errato collegamento dei poli potrebbe dann...

Page 31: ...l primo avvio attiva la funzione Select Safety È un processo che consente all utente di selezionare la lingua del display e il tipo di normativa prima di iniziare il normale funzionamento 9 Prima di aver completato l impostazione della normativa l inverter non potrà funzionare in maniera normale anche se collegato correttamente all ingresso DC e all uscita AC 9 Il seguente diagramma illustra il pr...

Page 32: ...ra continua energia dal generatore solare alla rete pubblica In questo caso l LCD sarà verde Pac 7494W Vdc 403 420V Vac 230 5 232 3 231 1V Iac 10 5 11 2 10 7A Status Normal 21 04 12 15 01 2 Ripristino da guasto In determinate situazioni come ad esempio tensione e frequenza anomale l inverter deve scollegarsi dalla rete Dopo aver risolto il problema l inverter torna alla condizione di normalità Per...

Page 33: ...nta rossa e l allarme si attiva per avvisare l utente L utente può premere il pulsante OK sulla tastierina di navigazione per azzerare la notifica di guasto In questo caso controllare il messaggio Se non è possibile cancellare l avviso di guasto contattare l assistenza locale 4 Spegnimento Di notte o in caso di forte nuvolosità durante il giorno l inverter si spegne automaticamente In queste condi...

Page 34: ... 251V e 349V dal lato DC l inverter è In attesa Allo stesso tempo l inverter controlla le condizioni DC e AC e attende la connessione z Normale Lo stato Normale richiede che la tensione dal lato DC sia almeno 350V Per controllare il collegamento dei cavi DC l inverter tenta di regolare la potenza in entrata a ogni accensione Nel corso del processo l utente potrà osservare una variazione nella lett...

Page 35: ...funzionamento Per risparmiare energia lo schermo resta illuminato solo per i 3 minuti seguenti l ultima operazione Tuttavia in caso di guasto o errore oltre a diventare rosso lo schermo lampeggerà con frequenza di un secondo fino a quando l utente preme il tasto indicato dalle istruzioni a schermo 3 Allarme acustico Nei seguenti casi il registratore dati emetterà un avviso acustico z Guasto dell i...

Page 36: ...a destra del display mostra data e ora In caso di messaggio di avviso o errore la riga in basso che riporta lo stato viene automaticamente sostituita dal messaggio di errore L utente può modificare i quattro parametri di monitoraggio z Premere Z per evidenziare il parametro di monitoraggio nella prima riga Utilizzando i tasti Ⴄ e Ⴎ l utente potrà passare alla riga successiva z Premere OK per inizi...

Page 37: ...a media in un intervallo di 6minuti ogni punto rappresenta 500W il massimo numero di punti è 48 z Data Il lato superiore destro riporta la data corrente Per visualizzare il grafico relativo a un dato giorno premere Z e Y per eseguire la selezione 6 12 9 7 8 10 11 1 2 3 4 5 20 KW 20 04 ź ź 10 4 Grafico settimanale Premendo il tasto Ⴎ durante la visualizzazione del grafico giornaliero l LCD passerà ...

Page 38: ...guito I parametri di monitoraggio visualizzati in Informazioni di sistema sono z SN numero di serie dell inverter z Versione versione del firmware dell inverter z Memoria stato della memoria del registratore dati z Data Impostazione della data dell inverter z Ora Impostazione dell ora dell inverter z Allarme acustico Per Attivare On o Disattivare Off l allarme acustico z Lingua Impostazione della ...

Page 39: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 39 di 277 FR Illustrazione della sequenza visualizzata del registratore dati ...

Page 40: ...bile viene definito da 0 100 Pn Di solito vengono utilizzate le impostazioni 100 60 30 0 7 1 2 Riduzione della potenza attiva in funzione della frequenza Il principio di tale requisito consiste nell identificare l eccessiva fornitura di potenza come innalzamento della frequenza di rete La limitazione di potenza in funzione della frequenza dà luogo a una rapida reazione secondo gli improvvisi cambi...

Page 41: ...erter Soleil 3F TL supporta quattro modalità di potenza reattiva che l operatore di rete potrà utilizzare per il proprio impianto Il controllo del setpoint o la curva caratteristica sono regolabili tramite comunicazioni Di seguito è presente la descrizione di ciascun metodo 7 2 1 Controllo setpoint COSij L operatore assegna un valore fisso del fattore di potenza Cosij all interno dell intervallo con...

Page 42: ... potenza reattiva Q con intervallo di impostazione ammesso Q 6kVar a 6kVar per il modello 10kW La capacità di potenza in uscita del controllo setpoint Q può essere così illustrata L area verde indica il punto di funzionamento consentito ad esempio per il modello 10 kW b Capacità di uscita reattiva del controllo setpoint Q ...

Page 43: ...lle condizioni di rete La curva caratteristica prescritta COSij P dispone di quattro punti di regolazione e un limite cosij con impostazioni predefinite L intervallo consentito del limite cosij è 0 8 1 0 e per i punti di impostazione è 0 100 d Curva caratteristica COSij P con impostazioni predefinite La capacità di potenza in uscita della curva caratteristica COSij P può essere così illustrata L area v...

Page 44: ...one delle condizioni di rete La curva caratteristica prescritta Q U dispone di quattro punti di regolazione e un limite Q con impostazioni predefinite L intervallo consentito del limite Q S è 0 60 e per i punti di impostazione è 0 100 f La curva caratteristica Q U con impostazioni predefinite La capacità di potenza in uscita della curva caratteristica Q U può essere così illustrata L area verde in...

Page 45: ...r è stato progettato per essere di facile uso è possibile capirne facilmente lo stato leggendo le informazioni visualizzate sul display anteriore o tramite monitoraggio remoto La tabella seguente indica i messaggi visualizzati Matrice delle lingue dei messaggi visualizzati continua nella pagina seguente ...

Page 46: ... Datum dd mm yyyy Di Fecha dd mm yyyy Mar Data dd mm yyyy Mar Date dd mm yyyy mar Datum dd mm yyyy Di Date dd mm yyyy Wed Datum dd mm yyyy Mi Fecha dd mm yyyy Mie Data dd mm yyyy Mer Date dd mm yyyy mer Datum dd mm yyyy Wo Date dd mm yyyy Thu Datum dd mm yyyy Do Fecha dd mm yyyy Jue Data dd mm yyyy Gio Date dd mm yyyy jeu Datum dd mm yyyy Do Date dd mm yyyy Fri Datum dd mm yyyy Fr Fecha dd mm yyyy...

Page 47: ...ria dei pannelli FV Idc xx x xx xA Idc xx x xx xA Idc xx x xx xA Idc xx x xx xA IDC xx x xx xA Idc xx x xx xA Informazioni energia accumulata Etot xxxxxxxxx xkWh Etot xxxxxxxxx xkWh Etot xxxxxxxxx xkWh Etot xxxxxxxxx xkWh Etot xxxxxxxxx xkWh Etot xxxxxxxxx xkWh Energia per giorno Etoday xxx xkWh E heute xxx xkWh Ehoy xxx xkWh Eoggi xxx xkWh Ejour xxx xkWh E today xxx xkWh Ore di funzionamento H to...

Page 48: ...agna ITALIANO Français Francia Nederlands Olanda Standby in intervallo ingresso 200V 259V Status Standby Status Standby Estado En espera Stato Standby Etat En attente Status Standby Inizializzazione e attesa in intervallo ingresso 260V 349V Status Waiting Status Warten Estado En proceso Stato In attesa Etat Prêt Status Wachten Controllo rtete con tensioneDC 350V Status Checking xxxs Status Netz Pr...

Page 49: ...Freq réseau Netfreq fout Guasto isolamento del pannello FV Isolation Fault Isolationsfehler Def aislamiento Err Isolamento Défaut isolation Isolatiefout Rete C a non disponibile No Utility Kein Netz Red ausente Rete assente Réseau absent Net niet aanw Sovra tensione di rete PV over voltage DC Überspannung Sobretensión DC Sovratensione DC Surtention DC DC overspanning Memoria scheda SD insufficient...

Page 50: ... BUS DC Low DC Bus DC Bus zu tief Bus DC bajo DC Bus basso Entrée 1 faible DC bus laag Alto livello tensione del BUS DC High DC Bus DC Bus zu hoch Bus DC alto DC Bus alto Entrée 1 élevée DC bus hoog Lettura tra CPU Master e Slave non coerente Consistent Fault Konsistenzfehler Defec Coherencia Err processore Err processeur CPU fout Versione firmware DSP e CPU slave non corrisponde M S Ver Fault M S...

Page 51: ...annello FV PV Connect Fault PV Verbdg fehler Defecto conex PV Err conness PV Err Connect PV PV verbind fout Errore avvio IGBT Inv Start Fault Inv Start Fault Def arranque Inv Err attivazione Déf Démarrage Inv Start Fault Ventola interna di raffreddamento non funzionante Internal Fan Lock Lüfter blockiert Bloq vent Intern Ventil int blocc Verr Ventil Int Int vent geblokk Ventola esterna di raffredd...

Page 52: ...ania ESPAÑOL Spagna ITALIANO Français France Nederlands Dutch Messaggi registrazione generali di sistema Press OK to Clear OK um zu Löschen Borrar Pulse OK Premi OK x reset OK suppression Druk OK om te wissen No Daily Records Keine Tagesaufzeichng Dia No registro NO Dati giorno Pas aff jour Geen dagrecords No Weekly Records Keine Wochenaufzeichn Sem NoRegistro NO Dati settim Pas aff semaine Geen w...

Page 53: ...di diversi inverter Anche l aggiornamento del firmware viene eseguito tramite questa interfaccia Collegamento del PC portatile all inverter tramite cavo adattatore da USB tipo A a USB tipo B 9 2 Slot comunicazioni RS 485 L inverter FV è dotato di un ulteriore slot da utilizzare per un interfaccia di comunicazione Tramite una scheda RS 485 Montata di serie o compatibile è possibile ampliare la funz...

Page 54: ...orretta per garantirne l impermeabilità Scheda RS485 dotata di due porte RJ45 con indicatori a LED una morsettiera per il cablaggio e un dip switch terminale a resistenza per il bus comunicazioni come illustrato nella figura precedente Il led PWR Alimentazione viene utilizzato per indicare la connessione della scheda RS 485 sarà illuminato in verde se l inverter è attivo e fino a quando la scheda ...

Page 55: ...rante il trasferimento del segnale La seguente tabella indica la piedinatura delle porte RJ45 della scheda RS485 Avviso cablaggio RS485 La presa è dotata di alimentazione DC Il piedino 7 e il piedino 8 della porta RJ45 vengono utilizzati per l alimentazione DC Assicurarsi di non collegare altri dispositivi a questa porta per evitare danni PIN DENOMINAZIONE Tensione 1 Tx s400mVp p s15Vp p 2 Tx 3 Rx...

Page 56: ...e scheda RS485 Connessione scheda RS485 È possibile collegare un cavo Ethernet tra qualsiasi porta RJ45 di ciascuna scheda RS485 Il cavo deve essere del tipo Diretto Connessione con cavo Ethernet tipo A per scheda RS485 Connessione con cavo Ethernet tipo B per scheda RS485 ...

Page 57: ...lizzato per le connessioni standard della scheda RS485 come indicato dalla figura in basso Come terminatori della scheda RS485 sono stati utilizzati cavi twisted pair Connessioni cavo twisted pair per scheda RS485 Come connessione standard per la scheda RS485 è anche possibile utilizzare una combinazione di cavo twisted pair e cavo Ethernet come da figura in basso Combinazione connessioni per sche...

Page 58: ...h resistenze terminali Il dip switch può essere utilizzato per configurare la scheda RS485 dell ultimo inverter sulla stessa linea come terminale della comunicazione Dip switch attivati Stato di attivazione disattivazione del dip switch Portando il piedino 1 e il piedino 2 del DIP Switch in posizione ON nella scheda RS485 dell ultimo inverter questo funzionerà come terminale Tale configurazione è ...

Page 59: ... spento La scheda non è inserita a fondo Inserirla nuovamente Verificare che l inverter sia attivo Verificare se l inverter è spento Verificare eventuali danni alla scheda RS485 Il led giallo è spento Verificare il normale funzionamento dell inverter Verificare la correttezza del cablaggio consultando il capitolo 3 1 per la definizione della piedinatura RJ 45 Verificare che la lunghezza dei cavi n...

Page 60: ...4 1 i Se nella comunicazione RS485 è connesso un unico inverter o se l inverter FV è l ultimo della connessione seriale è necessario impostare lo switch SW3 4 in posizione ON i Se nella comunicazione RS422 è connesso un unico inverter o se l inverter FV è l ultimo della connessione seriale è necessario impostare lo switch SW3 3 e lo switch SW3 4 in posizione ON i Inserire la scheda nell apposito s...

Page 61: ...ON ON 9600 3 Riservato DIP8 1 2 3 4 5 6 7 8 ON DIP ID Function Dip Description 4 Selezione Protocollo DIP1 2 1 2 3 4 DIP DIP 2 DIP1 PROTOCOL OFF OFF Modbus Function OFF ON ON OFF ON ON 5 Carico RS485A DIP3 1 2 3 4 DIP ON DIP 3 OFF No DIP 3 ON 120Ohm 6 Carico RS485B DIP4 1 2 3 4 DIP ON DIP 4 OFF No DIP 4 ON 120Ohm LED YELLOW LED Modbus communication GREEN LED Internal state Spento OFF Nessuna comun...

Page 62: ...ata impotazione dei parametri Verificare la connessione Verificare la impostazioni relative alle resistenze di terminazione Verificare le impostazioni dei DIP SWITCH CARATTERISTICHE TECNICHE Nella tabella di seguito le caratteristiche tecniche della scheda di interfacciamento Modbus Feature Specification Alimentazione 12VDC Descrizione Scheda di conversion protocollo Modbus per inverter solari 3F ...

Page 63: ...sue 2015 04 21 Pagina 63 di 277 FR 9 7 Interfaccia USB Registratore dati Il registratore dati è dotato di un connettore USB tipo B da collegare all interfaccia USB del PC Prima dell uso aprire il coperchio della presa USB ...

Page 64: ...20k model 8717 8717VAR 0 90 0 90pf Type A B P lock in 10 100 P lock out 5 Node X axis 80 120 Node Y axis 43 6 43 6 V lock in 230 0 253 0V V lock out 207 0 230 0V Node X axis 0 100 Node Y axis 0 90 0 90pf OK OK OK OK OK Reactive Power Func Mode Off Value N A Press OK over 5s to change the setting Reactive Power Func Mode Const Q Value 1000VAR Press OK over 5s to change the setting Reactive Power Fu...

Page 65: ...o B I PC con Windows ME 2000 e XP Vista Windows 7 non necessitano di driver per l accesso al registratore dati I PC con Windows 98 devono utilizzare il driver per accedere ai dati del registratore 2 Collegare il cavo adattatore USB al PC Se il Registratore dati è correttamente collegato al PC il led visualizzerà CONNESSIONE USB 3 Fare clic su Computer Disco rimovibile sul PC 4 Copiare la cartella ...

Page 66: ... Pagina 66 di 277 FR 6 Selezionare il periodo desiderato con inizio da Date from e termine a Date to Fare clic sul pulsante Import 7 Selezionare il file DAILY dat nella cartella DAILY precedentemente salvata Fare clic sul pulsante Open ...

Page 67: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 67 di 277 FR 8 Fare clic sul pulsante View Il software elaborerà i dati registrati 9 Fare clic sul pulsante Export ...

Page 68: ...clic sul pulsante Save I dati saranno memorizzati nella directory selezionata sul PC in formato CSV 11 Fare clic sul pulsante OK 12 Fare doppio clic sul file DAILY CSV nella directory selezionata del PC Sarà possibile gestire tali dati utilizzando Microsoft Excel ...

Page 69: ... inverter spegnendo l interruttore AC 2 Scollegare il lato DC dell inverter 3 Controllare cablaggio e isolamento DC e AC 4 Ripristinare il collegamento AC DC e verificare lo stato dell inverter 5 Se il problema persiste aggiornare il firmware secondo le istruzioni o sostituire l inverter Note Durante le procedure indossare guanti isolati Guasto dell isolament o La corrente di terra rilevata dall i...

Page 70: ...e e ricollegare la rete AC per provare se l inverter funziona normalmente 2 Se il problema persiste controllare la lettura della rete AC sul display LCD dell inverter 3 Se la lettura è all interno delle specifiche verificare la connessione dell impianto incluso per primi polarità e sicurezza 4 Trovare i dispositivi ad alto assorbimento nei pressi dell impianto AC 5 Consultare il gestore della rete...

Page 71: ...legare tutti gli e dell FV 2 Attendere 1 minuto 3 Dopo che nulla viene visualizzato sull LCD ricollegare di nuovo la DC e controllare 4 Se il messaggio di errore si ripresenta dopo il riavvio chiamare l assistenza 1 Verificare che l installazione sia configurata secondo le specifiche 2 Ripetere le azioni menzionate nella colonna a sinistra 3 Se il problema persiste aggiornare il firmware alla vers...

Page 72: ...l BUS DC all interno dell inverter è più bassa del previsto La tensione ingresso DC che alimenta il BUS DC è troppo bassa Guasto sensore DC Anomalia sensore DC all uscita 1 Anomalia firmware operativo 2 Anomalia rilevamento corrente sensore di Hall 1 Scollegare FV e FV dall ingresso e riavviare l unità 2 Se non funziona chiamare l assistenza 1 Ripetere le azioni menzionate nella colonna a sinistra...

Page 73: ...olazione dell aria intorno al dissipatore di calore non sia bloccata 9 Controllare la presenza di corrosione specialmente sui punti di connessione 9 Controllare periodicamente la fermezza delle connessioni 9 Pulire regolarmente l esterno dell unità con un panno umido per impedire l accumulo di polvere e sporco sull inverter Mantenere l etichetta di garanzia in perfette condizioni 9 Per ottenere pr...

Page 74: ... SOLEIL 3F TL10K 1 Scollegare l alimentazione AC e DC dell inverter FV 2 Svitare tutte le viti del modulo ventola come indicato dalla figura in basso 3 Estrarre il modulo ventola scollegando l adattatore del cavo come indicato dalla figura in basso 4 Se necessario pulire delicatamente la ventola con un panno umido o una spazzola morbida 5 Se il modulo ventola è danneggiato o guasto sostituirlo 6 M...

Page 75: ...dicato dalla figura in basso 3 Estrarre il modulo ventola scollegando l adattatore del cavo come indicato dalla figura in basso 4 Se necessario pulire delicatamente la ventola con un panno umido o una spazzola morbida 5 Se il modulo ventola è danneggiato o guasto sostituirlo 6 Montare il modulo ventola eseguendo la procedura precedente al contrario 7 Verificare che l inverter riprenda il normale f...

Page 76: ...dicato dalla figura in basso 3 Estrarre il modulo ventola scollegando l adattatore del cavo come indicato dalla figura in basso 4 Se necessario pulire delicatamente la ventola con un panno umido o una spazzola morbida 5 Se il modulo ventola è danneggiato o guasto sostituirlo 6 Montare il modulo ventola eseguendo la procedura precedente al contrario 7 Verificare che l inverter riprenda il normale f...

Page 77: ...nsione di avviamento 350 V Tensione di spegnimento 200V Tipico Intervallo tensione di esercizio 250 1000V Intervallo nominale tensione MPPT piena potenza 350 850 V 400 850 V 450 850 V Efficienza MPPT 99 Numero MPPT 2 Max potenza DC 10500W 15750W 21000W Max corrente DC 16A 2 20A 2 23A 2 Max numero stringhe in parallelo 2 2 2 2 3 2 Sezionatore esterno DC 20A x 2 25A x 2 30A x 2 Max corrente reiettat...

Page 78: ...merless Assorbimento potenza standby notte ู 20W ู 1W ู 20W ู 1W ู 20W ู 1W Grado protezione Telaio IP65 Ventola IP55 Dissipazione calore Raffreddamento forzato ventola velocità variabile in funzione temperatura dissipatore Livello rumorosità ู 55dB A Intervallo temperatura di esercizio 20 60ഒ Range di temperatura con piena potenza in uscita 20 45ഒ Max potenza in uscita 600 C tensione nominale dec...

Page 79: ...d integrato Opzionale rimovibile Riferimenti normativi Normativa di interfaccia verso rete VDE AR N 4105 VDE0126 1 1 A1 VDE0126 1 1 RD1699 G83 1 1 G59 Issue 2 CEI0 21 Sicurezza IEC 62109 1 2010 EN 62109 1 2010 IEC 62109 2 2011 EN 62109 2 2011 Compatibilità elettromagnetica EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 Sezionatore DC EN 60947 1 EN 60947 3 CE Direttiva bassa tensione 2006 95 EC EMC 20...

Page 80: ...V 262V 250V Fattore di potenza 0 9 lagging leading 0 99 Tolleranza tensione better than 1 N A Tooleranza frequenza better than 0 1 N A Intervallo frequenza di esercizio 1 47 5 51 5Hz Disconnection within 0 2seconds 2 Back frequency point The same as the red curve Before disconnection Impostazione di fabbrica Valore di frequenza 47 5 Hz 51 5Hz 47 55 Hz 51 45Hz Tempo di riconnessione 1 60s 85 110 vo...

Page 81: ...di superamento intervallo tensione di esercizio 15 10 15 1 5 secondi 1 5 secondi 0 2 secondi Impostazione valore tensione nel firmware 198V 250V 262V Intervallo frequenza di esercizio 48Hz 50 5Hz 3 secondi 0 5 secondi Riconnessione 50Hz se sovrafrequenza Impostazione valore frequenza nel firmware 48 05 Hz 50 45 Hz Tempo riconnessione NA Tempo riconnessione Impostazione FW 180 secondi Tempo disconn...

Page 82: ... 3F TL15K SOLEIL 3F TL20K Normativa di riferimento servizi di rete VDE 0126 1 1 Limite per singola fase NA Intervallo tensione di esercizio 230V 400V 20 15 Tempo disconnessione in caso di superamento intervallo tensione di esercizio 5 0 2 secondi 10 minuti Impostazione di fabbrica Valore di tensione 6 187V 262V 250V Tooleranza frequenza 47 5 50 2Hz Disconnessione entro 0 2 secondi quando la freque...

Page 83: ... Tempo disconnessione S2V 0 2s 0 2s Frequenza S2 47 0 50 0Hz 50 0 52 0Hz Valore di fabbrica frequenza S2 47Hz 51Hz Tempo disconnessione S2 F 0 10 5 00S 0 10 5 00S Valore di fabbrica Tempo disconnessione S2F 4s 1s Urva di limitazione Potenza P in funzione della sovreafrequenza di rete Statismo 2 5 Impostabile 2 4 Valore di default può essere disabilitato abilitato Tempo di attesa prima della riconn...

Page 84: ... 6537 Var 6537 Var 48 43 P 20kVA Cosfi 1 P 20KW Q 0 VAR Cosfi 0 9 Ͳ P 18KW Q Ͳ 8717 Var 8717 Var 48 43 P 2 Const PF Ͳ 0 90 0 90 pf 3 Curve Q U with type A B P Lock in 20 Pn P Lock out 5 Pn Node1 90 43 6 Q S Node2 92 0 Q S Node3 108 0 Q S Node4 110 43 6 Q S 4 Curve PF P Type A V Lock in 241 5 V V Lock out 230 0 V Node1 20 1 00pf Node2 40 1 00pf Node3 50 1 00pf Node4 90 0 90pf Curve Curve PF P Type ...

Page 85: ... 184V 1s FĻ 47Hz 4s FĹ 52Hz 1s Slope 2 4 2 In CEI 0 21 I range di tensione e frequenza e I tempi di disconnessione sono tarabili S1 Valore medio di tensione in una finestra temporal di 10 minuti 3 L inverter parte comunque quando I valori di frequenza e tensione sono compresi tra 49 9 50 1hz 195 5 253V incluso il primo avviamento ...

Page 86: ...produttore per le istruzioni di smaltimento Non smaltire l inverter come rifiuto comune Eseguire lo smaltimento dell inverter al termine del suo ciclo di vita ai sensi delle disposizioni locali relative allo smaltimento delle apparecchiature elettriche ed elettroniche Nota Contattare il fabbricante o il rivenditore per le istruzioni relative allo smaltimento ...

Page 87: ...so di problemi tecnici relativi al prodotto contattare la linea di assistenza Siel Per ricevere assistenza sarà necessario comunicare le seguenti informazioni Tipo inverter Numero di serie dell inverter FV Tipo e numero dei pannelli FV collegati Messaggio di errore Metodo di comunicazione ...

Page 88: ...fici di carico sono normali diagrammi di efficienza relativi a VCC e PCA e la potenza di uscita nell intervallo di esercizio può essere determinata dai diversi livelli di tensione di ingresso come curva di potenza illustrata di seguito Modello Curva di potenza SOLEIL 3F TL10K SOLEIL 3F TL15K SOLEIL 3F TL20K ...

Page 89: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 89 di 277 FR 17 2 Diagramma efficienza ...

Page 90: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 90 di 277 FR ...

Page 91: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 91 di 277 FR SIEL Grid Tied PV inverter SOLEIL 3F TL10K DE IT ES UK SOLEIL 3F TL15K DE IT ES UK SOLEIL 3F TL20K DE IT ES UK Installation and Operation Manual ...

Page 92: ...1 6 1 DC SWITCH USAGE 121 6 2 INITIALIZATION FOR REGULATION TYPE SETTING 121 6 3 OPERATING MODES 122 6 4 USING THE LCD DISPLAY AND DATA LOGGER 125 7 POWER MANAGEMENT 130 7 1 ACTIVE POWER 130 7 1 1 ACTIVE POWER REDUCTION 130 7 2 REACTIVE POWER 131 8 INVERTER OPERATING STATUS 135 9 COMMUNICATIONS 144 9 1 USB ON INVERTER 144 9 2 COMMUNICATIONS SLOT FOR RS 485 144 9 3 RS485 CARD CONFIGURATION 147 9 4 ...

Page 93: ...IV351 Rev04 Date Issue 2015 04 21 Page 93 di 277 FR 15 DISPOSAL 177 16 CONTACT INFORMATION 178 17 EFFICIENCY CHART 179 17 1 LOAD GRAPHS 179 17 2 EFFICIENCY CHART 180 ...

Page 94: ...PV inverter or simply Inverter This Grid PV inverter is a highly reliable product due to its innovative design and perfect quality control Such an Inverter is used in high demand grid tied PV systems If you encounter any problems during installation or operation of this unit first check this manual before contacting your local dealer or supplier Instructions inside this manual will help you solve ...

Page 95: ...capacitors Before handling the device please allow at least 1 minute after the power is disconnected Public Utility only The PV inverter is designed to feed AC power directly to the public utility power grid Do not connect the AC output of this device to any private AC equipment Hot Surfaces Although designed to meet international safety standards the PV inverter can become hot during operation Do...

Page 96: ...z Acts of third parties atmospheric discharges excess voltage chemical influences natural wear and tear and for loss and damage in transit z Improper testing operation maintenance adjustment repair or any modification of any kind not authorized in writing by the Inverter supplier z The Inverter has been connected to other equipment with which it is not compatible z Use and application beyond the d...

Page 97: ... controls the current amplitude according to the PV Panel power supply The Inverter always tries to convert the maximum power from your PV panel s AC Junction Unit This interface between Utility and PV inverter must consist of AC breaker and connecting terminals To comply with local safety standards and codes the connection system should be designed and implemented by a qualified technician The Ut...

Page 98: ...verters converts direct current DC power generated by PV modules into alternating current AC which is compatible with the local electricity distribution network also called the public utility or grid system Model Appearance Dimension mm SOLEIL 3F TL10K 548 565 275 SOLEIL 3F TL15K 548 565 275 SOLEIL 3F TL20K 548 565 275 ...

Page 99: ...t or maintenance or even for calling service in the future Model Number and Serial Number On the left side of SIEL Grid tied PV inverter shows the rating label of the Inverter The rating label states the Type Brand Name Model Name Specifications and the Serial Number of the Inverter When encounter any difficulties during installation or operation please record the Serial Number SN before contactin...

Page 100: ...85 card installation users can link with the Inverter and monitor its real time operation and status remotely 5 Heat Sink A hardware device that used to dissipating heat into the surrounding air 6 USB Interface Connect this port directly to your PC via an USB cable users can communicate with the Inverter through specific program tool 7 AC Output Terminal For wiring AC output cable to the grid with...

Page 101: ...IV351 Rev04 Date Issue 2015 04 21 Page 101 di 277 FR SOLEIL 3F TL10K DE IT ES UK SOLEIL 3F TL15K DE IT ES UK SOLEIL 3F TL20K DE IT ES UK ...

Page 102: ...od 5 years Storage Media 2GB SD card support up to 32GB Data Download Via B type USB Features of Graphic Data Logger Multicolored back light The backlight of the LCD will be changed according to its status There are 3 colors of backlight and their indications are z Green Start up and normal status z Red Fault Status In this status Inverter disconnected from grid due to system fault or Inverter fai...

Page 103: ...ion the deviation of accuracy is up to 5 The reading tolerance may vary from 2 to 5 depending on the operating condition If precise measurement of the system status is needed adequate equipment such as power meter shall be installed Appearance of LCD Display z LCD 128 x 64 graphic monochrome z Navigation Pad Ⴄ Ⴎ Z Y and OK in the center z Back light 3 colors Pac 7494W Vdc 403 420V Vac 230 5 232 3 ...

Page 104: ... additional remote device will be required such as external data logger Maximum Power Point Tracking MPPT A PV inverter must be able to convert the maximum power from any PV panel Due to its advanced design this PV inverter can track the maximum power from the PV panel in any condition When the displayed power on the LCD output does not change dramatically the Inverter is converting the maximum po...

Page 105: ...e needed The 3 Accessory Box contains items that listed in the table below Items Quantity Item Descriptions Figure User s Manual 1 Installation and Operation Manual AC Cover 1 Top enclosure used for the AC Terminal DC Connector Extractor 1 Disconnecting tools for the DC connector Rubber Bushing 1 Accessories for the AC wires connection Nylon Drive Anchor 6 Accessories for the bracket installation ...

Page 106: ...operated at locations where the ambient temperature is up to 60qC However for optimal operation it is recommended that Inverter is installed where the ambient temperature is between 0 to 45qC Warning Do not expose the PV inverter to direct sunlight Direct sunlight increases the internal temperature that may reduce conversion efficiency Note Although the Inverter is designed for outdoor application...

Page 107: ...space above and 90cm space below the Inverter 3 For maintenance purpose please keep Inverter 30cm distance at least from each other Note Don t mount PV inverter on top of another one or other heat radiating sources unless it is inevitable in that case 100cm spacing at minimum from each other is required to provide proper ventilation effect 4 Fix the Bracket by using all of six mounting holes the b...

Page 108: ...IV351 Rev04 Date Issue 2015 04 21 Page 108 di 277 FR Mounting Bracket Notes Diameter for the safety screw is at 10mm2 ...

Page 109: ...o lift up with the proper lifting tool in order to move PV inverter to the installed location when the hanging irons installed on the PV inverter as illustrated Hanging PV inverter to the install location Optional Notes Proper lifting tool must be used for the lifting please beware ...

Page 110: ...Date Issue 2015 04 21 Page 110 di 277 FR 6 Mount the Inverter onto the bracket as illustrated Mount the PV inverter on the Wall 7 Check and ensure the device is properly fixed to the bracket in the proper direction ...

Page 111: ... 3 Find the AC output wires with recommended size as indicated in the table below L1ᇬL2ᇬL3ᇬNᇬPE1 must use wire with minimum gauge indicated in following table Model SOLEIL 3F TL10K SOLEIL 3F TL15K SOLEIL 3F TL20K Power W 10000 15000 20000 Max AC current 16 A 24 A 30A Max AC Cable Size 10 AWG 8 AWG 8 AWG Note Do not use cables where losses will exceed 1 PE2 wire area must be of same gauge as PE1 do...

Page 112: ...re before connecting The stripped length of AC wire is about 10 mm to 12 mm 7 Connect the AC wires to the AC terminal block correspondingly and tighten it properly Suggestion After Connecting After tightening AC wires to the AC terminal block be sure to check its tightness by pulling the wire one by one ...

Page 113: ...firstly And then disconnected the AC power L1 PhaseᇬL2 PhaseᇬL3 Phase and N Phase of PV inverter at the same time in order to protect the PV inverter itself If user fails to comply with the above Important Reminder PV inverter and the connected equipment will be damaged 8 Fix the AC output cover back with a screwdriver 9 Twist the connector cable gland to lock the bushing and cable together firmly...

Page 114: ...ng to the AC Junction Unit AC utility The AC Junction unit is an interface between PV inverter and the Public Utility It may consist of an electrical breaker fuse surge protector and terminals for connection of the PV inverter to the Public Utility This AC Junction Unit must be designed by a qualified technician to comply with local safety standards requirement Model SOLEIL 3F TL10K SOLEIL 3F TL15...

Page 115: ...2 SOLEIL 3F TL15K ู1000V 30A 2 SOLEIL 3F TL20K ู1000V 34 5A 2 Attention Please select suitable external DC power plug cable connector with rating current higher than Max DC current of the Inverter Attention Please select suitable PV panel which has short circuit current less than Max DC current of PV Inverter 9Always connect PV modules positive terminal to PV inverter DC positive terminal negative...

Page 116: ...le No Specific type with earthed negative pole No Note Please consult with your dealer for PV module type suggestion Requirement of PV Module For connecting DC input of one single Inverter connected strings must consist of modules of the same type Do not share the DC input connection with other Inverter The number orientation and tilt of panels may differ for different application DC Connector Mod...

Page 117: ...ate Issue 2015 04 21 Page 117 di 277 FR The following table lists those connector pairs MultiContact Amphenol PV KST4 6I Male Connector Helios H4 Male Connector PV KBT4 6I Female Connector Helios H4 Female Connector ...

Page 118: ...phenol DC connector by using a connector extractor as below figure shown the connector extractor shall be found in accessories box shipped along with package of Inverter 3 Insert the tool through the connector in either way to cramp its clips As below figure shown 4 After cramping the clips pull the connector slightly downward to disassemble the DC cable ...

Page 119: ...f DC switch if present and disconnect DC cables at last Public Utility only Don t turn the connector around in anti clockwise direction otherwise DC connector assembled to the chassis of the Inverter may become loose Attention Before connecting DC power to the Inverter be sure to check polarity of each DC input pair is correct by multi meter Incorrect polarity connection would permanently damage t...

Page 120: ...or fuse in the unit Under normal operation the Data Logger LCD shows the following as an example Pac 7494W Temperature 26 8 C Iac 10 5 11 2 10 7A Vac 219 4 219 3 219 3V Status Normal 21 04 12 15 01 9 When the display is green the Inverter is feeding power to the grid Under such condition you have installed the Inverter successfully Warning Don t disconnect DC power or cables while the Inverter is ...

Page 121: ...rt up as a process in which user is able to select the intended language displayed and regulation type before starting normal operation 9 The Inverter will not able to operate normally before regulation setting is completed even though it is connected correctly at both DC input and AC output 9 The following flowchart illustrates the process of Select Safety For example if users in German need to s...

Page 122: ...4 12 15 01 7 Recovery from Fault In some situations such as abnormal voltage and frequency the Inverter has to disconnect from grid After the situations are cleared Inverter recovers to normal condition For the coming 48 hours the LCD backlight will be yellow as following picture If there is no further abnormal event after 48 hours of operation the color switches back to green again Pac 7494W Vdc ...

Page 123: ...23 di 277 FR be cleared please contact with your local service No Utility Press OK to Clear 9 Shutdown During night or heavily cloudy day the Inverter automatically shuts down In this condition Data Logger and the navigation pad are inactive ...

Page 124: ...aiting Between 251V and 349V at DC side the Inverter is in Waiting state In the meantime the Inverter keeps checking both DC and AC conditions and waiting for connection z Normal To be in Normal state voltage on DC side must be 350V or above To check the DC wire connection this Inverter tries to change its input power for every starting up During the process user can see the DC power reading drift...

Page 125: ...e light remains illuminated only for 3 minutes after last operation However in case a failure or error occurs other than the backlight goes red the backlight flashes every second until user presses the key according to instruction on the LCD 7 Audio Alarm To inform the user data logger will emit audio alarm in cases of following z Inverter failure z Memory capacity of data logger is less than 5 re...

Page 126: ...time and date On occurrence of a warning or error message the bottom line Status is automatically replaced by the error message The user can change the four monitoring parameters z Press Z to highlight the monitoring parameter at the first line By using Ⴄ and Ⴎ the user can shift to the next line z Press OK to begin setting the monitoring parameter z Press Ⴄ or Ⴎ to select the monitoring parameter...

Page 127: ...wer axis y axis From 0 to 24KW Each point is the averaged power during 6 minute interval each dot means 500W the maximal dot number is 48 z Date On the upper right corner the date of present display is shown To see daily graph of expected day press Z and Y to select 6 12 9 7 8 10 11 1 2 3 4 5 20 KW 20 04 ź ź 10 10 Weekly graph Press the Ⴎ of daily display LCD changes to the Weekly Display as below...

Page 128: ... version etc as shown below System Display S N 0123456789ABCDEF Version MB 20 00 27 Memory 0 3 Date 21 04 2011 Sat Time 15 01 19 GMT 08 Audible Alarm On Language English The following are the monitoring parameters shown in System Display z SN Serial number of the Inverter z Version Firmware version of the Inverter z Memory Memory status of the Data Logger z Date Date setting of the Inverter z Time...

Page 129: ...IV351 Rev04 Date Issue 2015 04 21 Page 129 di 277 FR Illustration of Data Logger Display Sequence ...

Page 130: ...ed as 0 100 Pn In general the settings of 100 60 30 0 are commonly used in several power management provisions 7 1 2 Frequency dependent active power reduction The principle for this requirement is that the energy oversupply can be recognized as gird frequency rise The frequency dependent active power limitation will get a quick reaction while suddenly frequency changes in the grid If the frequenc...

Page 131: ...opposite There are four reactive power mode supported by Soleil PV inverter each one of them can be specified by the network operator for their plant use Either set point control or characteristic curve is adjustable by the communication The capability of each method is described as follows 7 2 1 COSij Set Point Control A fixed value of the power factor Cosij is assigned by the network operator with...

Page 132: ... power Q is assigned by the network operator with the permissible setting range Q 6kVar to 6kVar with 10kW model The output power capability of Q set point control can be shown as Green region means the permissible operating point take 10kW model for example c Reactive output capability of Q set point control ...

Page 133: ...ant depending on the network conditions The prescribed COSij P characteristic curve has four adjustable nodes and one cosij limit with default setting The permissible range of cosij limit is 0 8 1 0 and for node setting is 0 100 d The COSij P characteristic curve with default setting The output power capability of COSij P characteristic curve can be shown as Green region means the permissible operating...

Page 134: ...ation plant depending on the network conditions The prescribed Q U characteristic curve has four adjustable nodes and one Q limit with default setting The permissible range of Q S limit is 0 60 and for node setting is 0 100 f The Q U characteristic curve with default setting The output power capability of Q U characteristic curve can be shown as Green region means the permissible operating point t...

Page 135: ...er is designed to be user friendly the status of the Inverter can be easily understood by reading the information shown on the front panel display or through remote monitoring All possible messages are listed in the following table The Language Matrix of Display Messages Continue in next page ...

Page 136: ...te SD xx x Geheugen xx x Date Information Date dd mm yyyy Sun Datum dd mm yyyy So Fecha dd mm yyyy Dom Data dd mm yyyy Dom Date dd mm yyyy dim Datum dd mm yyyy Zo Date dd mm yyyy Mon Datum dd mm yyyy Mo Fecha dd mm yyyy Lun Data dd mm yyyy Lun Date dd mm yyyy lun Datum dd mm yyyy Ma Date dd mm yyyy Tue Datum dd mm yyyy Di Fecha dd mm yyyy Mar Data dd mm yyyy Mar Date dd mm yyyy mar Datum dd mm yyy...

Page 137: ...liano Italiano Italien Italiaans Display in French France Französisch Frances Francese Français Frans Display in Dutch Dutch Holländisch Holandés Olandese Hollandaise Nederlands Meter Information Messages Meter Information Messages Operation Status ENGLISH DEUTSCH German ESPAÑOL Spanish ITALY Français France Nederlands Dutch The Real time output power Pac xxxxxW Pac xxxxxW Pac xxxxxW Pac xxxxxW Pa...

Page 138: ...peratura xx xºC Temperatura xx xºC Température xx xºC Temperatuur xx xºC Grid Voltage Vac xxx x xxx x xxx xV Uac xxx x xxx x xxx xV Vac xxx x xxx x xxx xV Vac xxx x xxx x xxx xV VAC xxx x xxx x xxx xV Uac xxx x xxx x xxx xV Grid Frequency Frequency xx xHz Frequenz xx xHz Frecuencia xx xHz Frequenza xx xHz Fréquence xx xHz Frequentie xx xHz Safety Selection Safety VDE0126 1 1 A1 Safety VDE0126 1 1 ...

Page 139: ...a Etat Prêt Status Wachten Check Grid in input range 350V and above Status Checking xxxs Status Netz Prüf xxxs Estado Chequeo xxxs Stato Test xxxs Etat Vérif xxxs Status Controle xxxs Inverter is feeding with the Grid Status Normal Status Normal Estado Normal Stato Normale Etat Connecté réseau Status Normaal A system fault or Inverter fault happened Status Fault Status Fehler Estado Defecto Stato ...

Page 140: ...frec red Err Freq rete Déf Freq réseau Netfreq fout Earth Fault of the PV Panel Isolation Fault Isolationsfehler Def aislamiento Err Isolamento Défaut isolation Isolatiefout AC Grid is not available No Utility Kein Netz Red ausente Rete assente Réseau absent Net niet aanw Input voltage is higher than specification PV over voltage DC Überspannung Sobretensión DC Sovratensione DC Surtention DC DC ov...

Page 141: ...fout Firmware version of DSP and Slave CPU is mismatch M S Ver Fault M S Ver Fehler Ver M E incomp FW incompatibile Err applicatif M S Ver Fout Output Relay is failed to start Relay Failure Relaisfehler Fallo relé Errore Relè Défaut relais AC Relaisfout Communication between Data and Slave CPU failed USB CONNECT USB angeschlossen Conexión USB Connessione USB Connection USB USB verbonden General In...

Page 142: ...ERR EEPROM EEPROM fout EEPROM abnormal Unknown Unbekant Fehler Desconocido Sconosciuto Err Inconnue Onbekend Protection for the DC BUS Bus Soft Timeout Bus Soft Timeout LimiteTiempo Bus Bus Soft Timeout Déf Com Bus Bus Soft Timeout General Inverter Fault Messages Operating Conditions ENGLISH DEUTSCH German ESPAÑOL Spanish ITALY Français France Nederlands Dutch Protection for the IGBT of inverter I...

Page 143: ... Dati giorno Pas aff jour Geen dagrecords No Weekly Records Keine Wochenaufzeichn Sem NoRegistro NO Dati settim Pas aff semaine Geen weekrecords No Error History Fehlerspeicher leer NoHistor Errores NO storico err Historique OK Geen foutenhistorie Please Wait Bitte warten Espere por favor Attendere prego Attendre SVP A U B wachten Error History Fehlergeschichte HistoricoErrores Storico errori Err ...

Page 144: ...rside of the device which allows user to use Pro Control to monitor the real time status of multiple Inverters Firmware upgrade is also conducted via this interface Connecting laptop PC to Inverter via USB type A to type B adapter cable 9 2 Communications slot for RS 485 PV inverter has an extended slot for an optional communication interface Through installing a RS 485 card or compliant card to e...

Page 145: ...assembled and installed in order to maintain waterproof grade of the unit RS485 Card equipped 2 RJ45 ports with LED indicators a terminal block for the wiring selection and a terminal resistor dip switch for the communication bus as above figure shown PWR Power LED is used to indicate the connectivity of RS 485 card it will light up in green when the inverter is active and as long as RS485 card ha...

Page 146: ...during signal transferring The following table is indicated the pin dentitions for the RS45 ports of RS485 RS485 Wiring Notification DC Power exists on the socket Pin 7 and Pin 8 of RJ45 port is used for the DC powered It is important to make sure do not connect other devices to this port It may damage your devices PIN NAME Voltage 1 Tx s400mVp p s15Vp p 2 Tx 3 Rx 400mVp p 15Vp p 4 GND 5 GND 6 Rx ...

Page 147: ...Ethernet cable can be connected either RJ45 port between each RS485 Card And the cable must be a Straight through Cable Type A Ethernet Cable Connection for RS485 Card Type B Ethernet Cable Connection for RS485 Card The wiring definition for the Straight through Cable that used to RJ45 port of RS485 card ...

Page 148: ...l blocks of RS485 card Twisted Wire Pairs Connection for RS485 Card A combination of the Twisted Wire Pair and Ethernet cable also can be applied as one of standard connections for the RS485 card as figure indicated below Combination Connection for RS485 Card When wiring RS485 card from Inverter to RS485 to RS232 Converter we connect opposite pins of RS485 which means Receive Pin to Transmit Pin a...

Page 149: ... as a final terminal point for the communication transmitting by turned on terminal dip switch Turned On Terminal Resistors Dip Switch Off and On Status of Terminal Resistor Dip Switch By pressing the pin 1 and pin 2 of DIP Switch in ON position from the RS485 card of last PV inverter as the terminal inverter Only the last inverter required to have this configuration For the please set it to off P...

Page 150: ...actions PWR Power LED is off RS485 card is not inserted well please insert it again Check whether inverter is active Check whether Inverter is shut down Check whether RS485 card is damaged Yellow LED is off Check whether Inverter runs normally Check whether the cables and wiring are set up properly please refer to chapter 3 1 RJ 45 pin definition Check whether the cables are too long for proper tr...

Page 151: ...n 0 22mm2 AWG24 1 i If in the RS485 is connected one PV Inverter only or if the PV Inverter is the last in the serial connection it is necessary to set the SW3 4 to ON position i If in the RS422 is connected one PV Inverter only or if the PV Inverter is the last in the serial connection it is necessary to set both SW3 3 and SW3 4 to ON position i Fit the PCB in the SLOT and fix the protection cove...

Page 152: ...4 5 6 7 8 ON DIP ID Function Dip Description 4 Protocol Selection DIP1 2 1 2 3 4 DIP DIP 2 DIP1 PROTOCOL OFF OFF Modbus Function OFF ON ON OFF ON ON 5 RS485A load DIP3 1 2 3 4 DIP ON DIP 3 OFF no load on line DIP 3 ON 120Ohm load on the line 6 RS485B load DIP4 1 2 3 4 DIP ON DIP 4 OFF no load on line DIP 4 ON 120Ohm load on the line LED YELLOW LED Modbus communication GREEN LED Internal state OFF ...

Page 153: ...NICAL FEATURES See the table below for the technical features of the board Feature Specification Insulated power supply SELV 12VDC Description Modbus Protocol conversion board for Solar inverters ModBus commands suppurated 0x03 single or multiple reading Configurable baud rate 1200 2400 4800 9600 bps Slave address Node 1 31 0 reserved via dip switches Serial connections 4 wires RS422 or 2 wires RS...

Page 154: ...20k model 8717 8717VAR 0 90 0 90pf Type A B P lock in 10 100 P lock out 5 Node X axis 80 120 Node Y axis 43 6 43 6 V lock in 230 0 253 0V V lock out 207 0 230 0V Node X axis 0 100 Node Y axis 0 90 0 90pf OK OK OK OK OK Reactive Power Func Mode Off Value N A Press OK over 5s to change the setting Reactive Power Func Mode Const Q Value 1000VAR Press OK over 5s to change the setting Reactive Power Fu...

Page 155: ...with Windows ME 2000 and XP Vista Windows 7 it is not necessary to install driver to access the data logger For PC with Windows 98 to access the data logger driver for the data logger is needed 2 Connect the USB cable adapter to PC LED will show USB CONNECT when Data Logger is connected to PC properly 3 Click My Computer Removable Disk in your PC 4 Copy the DAILY folder in the Removable Disk and p...

Page 156: ...IV351 Rev04 Date Issue 2015 04 21 Page 156 di 277 FR 6 Select Date from and Date to the period which you prefer Then click Import button ...

Page 157: ...e Issue 2015 04 21 Page 157 di 277 FR 7 Select DAILY dat file under your previous saved DAILY folder Then click Open button 8 Click View button and the log data will be processed by Pro Control software in few seconds ...

Page 158: ...IV351 Rev04 Date Issue 2015 04 21 Page 158 di 277 FR 9 Click Export button 10 Click Save button Then log data will be saved in CSV format in your preferred directory in your PC ...

Page 159: ...351 Rev04 Date Issue 2015 04 21 Page 159 di 277 FR 11 Click OK button 12 Double click DAILY CSV file in your preferred directory in your PC After that you can manipulate the log data with Microsoft Excel ...

Page 160: ...C side of Inverter by turn off the AC switch 7 Disconnect the DC side from the Inverter 8 Check both the AC and DC wiring and insulation 9 Reconnect AC DC connection check the status of Inverter 10 If the problem persists please Update the firmware according to instructions or Replace the Inverter Notes An insulation gloves must be wearing during procedures Isolation Fault The ground current detec...

Page 161: ...o see if inverter can be operated normally 12 If problem still occurred check the reading value of AC grid from the LCD display of Inverter 13 If reading value is within specification check the system connection including polarities and security first 14 Find the devices with high power consumption near the AC system 15 Consult the utility power supplier understand the grid conditions regarding th...

Page 162: ...minutes 7 After no display on LCD reconnect the DC again and check 8 If the fault message still appears again after restart call your local service 4 Make sure installation is configured under specification 5 Processes the same actions again as left column mentioned 6 If the problem still persists please try to Upgrade the latest firmware according to instruction or Replace the unit DC INJ High Th...

Page 163: ...uration of the PV Panel to ensure the it is used within specification 21 If the fault continues Update the firmware according to instructions or Replace the Inverter Low DC Bus DC voltage of DC inside Inverter is lower than expectation DC Input voltage that feed to DC BUS is too low DC Sensor Fault The DC sensor at output is abnormal 3 Operation firmware is Abnormal 4 Detected current of Hall sens...

Page 164: ...ittle or no sunlight the PV inverter may continuously start up and shut down This is due to insufficient power generated to operate the control circuits Warning Dangerous high voltage exists on both DC and AC wires and connections For end user Please do NOT touch any live parts ...

Page 165: ... points 9 Check If the fan guard is covered with debris or dust get rid of it if find any 9 Check heatsink to ensure no barrier blocking its air flow 9 Inspect for corrosion especially at connecting point 9 Verify all connections are firmly tightened periodically 9 Clean the exterior of the unit periodically with a damp cloth to prevent Inverter from accumulation of dust and dirt Keep warranty lab...

Page 166: ...Disconnect the AC power and the DC power of PV inverter 9 Unfasten all the screws of fan module as figure indicated below 10 Take off the fan module by disconnect its cable adapter as figure indicated below 11 Clean fan with damp cloth or soft brush tenderly if needed 12 If fan module is damaged or malfunctioned permanently please make a replacement by a new fan module 13 Assemble the fan module i...

Page 167: ... module as figure indicated below 10 Take off the fan module and disconnect its cable adapter as figure indicated below 11 Clean fan with damp cloth or soft brush tenderly if needed 12 If fan module is damaged or malfunctioned permanently please make a replacement by a new fan module 13 Assemble the fan module in the reverse order of above procedures 14 Check Inverter resumes normal operation afte...

Page 168: ... module as figure indicated below 10 Take off the fan module and disconnect its cable adapter as figure indicated below 11 Clean fan with damp cloth or soft brush tenderly if needed 12 If fan module is damaged or malfunctioned permanently please make a replacement by a new fan module 13 Assemble the fan module in the reverse order of above procedures 14 Check Inverter resumes normal operation afte...

Page 169: ...nitial feeding voltage 350 V Shutdown voltage Typical 200V Working voltage range 250 1000V MPPT Full rating voltage range 350 850 V 400 850 V 450 850 V MPPT efficiency 99 Number of MPP tracker s 2 Maximum DC power 10500W 15750W 21000W Maximum DC current 16A 2 20A 2 23A 2 Max number of parallel strings 2 2 2 2 3 2 External DC Circuit Breaker 20A x 2 25A x 2 30A x 2 Max Inverter Backfeed Current to ...

Page 170: ...fficiency ฺ97 2 ฺ97 0 ฺ97 2 General Data Topology Transformerless Power consumption standby night ู 20W ู 1W ู 20W ู 1W ู 20W ู 1W Protection degree Outdoor Chassis IP65 Fan IP55 Heat dissipation Force air cooling variable fan speed according to temperature on heatsink Acoustic noise level 55dB A Operating temperature range 20 60ഒ Continuous Output power temperature range 20 45ഒ Max O P power 600 ...

Page 171: ...Front Bezel Data logger Display 128 64 pixels Function key 5 Standard embedded Optional removable Normative references Grid interface regulation VDE AR N 4105 VDE0126 1 1 A1 VDE0126 1 1 RD1699 G83 1 1 G59 Issue 2 CEI0 21 Regular Safety IEC 62109 1 2010 EN 62109 1 2010 IEC 62109 2 2011 EN 62109 2 2011 EMC EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 DC Switch EN 60947 1 EN 60947 3 CE LVD 2006 95 EC ...

Page 172: ...15 10 0 1 seconds 0 1 seconds 0 2 seconds ู0 2 seconds Voltage value setting in the firmware 184V 264 5V 253V 187V 262V 250V Power factor 0 9 lagging leading 0 99 Voltage tolerance better than 1 N A Frequency tolerance better than 0 1 N A Operational frequency range 1 47 5 51 5Hz Disconnection within 0 2second 2 Back frequency point 1 4105 the same as the red curve Before disconnection Frequency v...

Page 173: ... excess operational voltage range 15 10 15 1 5 seconds 1 5 seconds 0 2 seconds Voltage value setting in the firmware 198V 250V 262V Operational frequency range 48Hz 50 5Hz 3 seconds 0 5 seconds Reconnection 50Hz if over frequency Frequency value setting in the firmware 48 05 Hz 50 45 Hz Reconnection time NA Reconnection time FW setting 180 seconds Disconnection time of excess DC current injection ...

Page 174: ...ection time of excess operational voltage range 10 14 7 20 13 10 15 1 5 s 0 5s 2 5s 1s 0 5s Voltage value setting in the firmware 210V 261V 184V 200 1V 253V 264 5V Operational frequency range 47Hz 50 5Hz 47Hz 47 5Hz 51 5Hz 52Hz 0 5s 0 5s 20s 21s 90s 91s 0 5s Frequency value setting in the firmware 47 05 Hz 50 45Hz 47Hz 47 5Hz 51 5Hz 52Hz Reconnection time 180s 180s Reconnection time FW setting Dis...

Page 175: ... 00S FW default setting 0 2s 0 2s S2 Frequency 47 0 50 0Hz 50 0 52 0Hz FW default setting 47Hz 51Hz S2 F Disconnection Time 0 10 5 00S 0 10 5 00S FW default setting 4s 1s Limitation curves of active power via frequency 2 5 Adjustable 2 4 as Default can be disable enable Reconnection time FW Setting wait 300 sec with frequency inside Value of frequency to reset the derating condition Slow Start aft...

Page 176: ... 108 0 Q S Node4 110 43 6 Q S 4 Curve PF P Type A V Lock in 241 5 V V Lock out 230 0 V Node1 20 1 00pf Node2 40 1 00pf Node3 50 1 00pf Node4 90 0 90pf Curve PF P Type B Node1 0 1 00pf Node2 5 1 00pf Node3 5 0 90pf Node4 90 0 90pf 1 CEI 0 21 LV S1 S2 LV MV has the same default setting VĹ 276V 0 5s VĻ 184V 1s FĻ 47Hz 4s FĹ 52Hz 1s Slope 2 4 2 In CEI 0 21 Voltage Frequency operation range disconnecti...

Page 177: ...e supplier for disposal instructions The Inverter must not be disposed of with the household waste Dispose of the PV Inverter at the end of its service life should be done in accordance with the disposal regulations for electronic waste which apply at the installation site at that time Note Please contact supplier or dealer for disposal instruction ...

Page 178: ...ave technical problems concerning this product please contact our service line We require the following information in order to provide you with the necessary assistance Inverter type Serial number of the PV Inverter Type and number of PV panel connected Fault message Communication method ...

Page 179: ...Load graphs are the typical efficiency charts that related to VDC and PAC is and the output power within the operation range can be determined by the different level of input voltage as power curve that shown in the following Model Power Curve SOLEIL 3F TL10K SOLEIL 3F TL15K SOLEIL 3F TL20K ...

Page 180: ...IV351 Rev04 Date Issue 2015 04 21 Page 180 di 277 FR 17 2 Efficiency Chart ...

Page 181: ...IV351 Rev04 Date Issue 2015 04 21 Page 181 di 277 FR ...

Page 182: ...ungsdatum 2015 04 21 Seite 182 von 277 FR Netzgekoppelte Wechselrichter für Photovoltaikanlagen SIEL SOLEIL 3F TL10K DE IT ES UK SOLEIL 3F TL15K DE IT ES UK SOLEIL 3F TL20K DE IT ES UK Installations und Bedienungsanleitung ...

Page 183: ... DES DC SCHALTERS NUR FÜR GERÄTE MIT DC SCHALTER 212 6 2 INITIALISIERUNG DER LÄNDEREINSTELLUNG 212 6 3 BETRIEBSZUSTÄNDE 213 6 4 BEDIENUNG DES LCD DISPLAYS UND DES DATENLOGGERS 216 7 NETZWERKDIENST 222 7 1 WIRKUNGSLEISTUNG 222 7 1 1 BEGRENZUNG DER WIRKLEISTUNG 222 7 2 BLINDLEISTUNG 223 8 BETRIEBSSTATUS DES WECHSELRICHTERS 227 Matrix der Sprachen der angezeigten Meldungen Fortsetzung nächste Seite 2...

Page 184: ...llungsdatum 2015 04 21 Seite 184 von 277 FR 14 2 ELEKTRISCHE SPEZIFIKATIONEN 263 14 3 NETZÜBERWACHUNG 266 15 ENTSORGUNG 272 16 KONTAKT 273 17 WIRKUNGSGRADKURVE 274 17 1 BELASTUNGSDIAGRAMME 274 17 2 WIRKUNGSGRADKURVE 275 ...

Page 185: ...och zuverlässiges Produkt auf Grund der sorgfältigen Planung und des angewandten Systems der Qualitätskontrolle Das Gerät ist für den Einsatz in anspruchsvollen mit dem Netz verbundenen Photovoltaiksystemen vorgesehen Sollten bei der Installation oder dem Betrieb des Gerätes Probleme auftreten schlagen Sie bitte immer zuerst in dieser Anleitung nach bevor Sie sich an Ihren Fachhändler oder Anbiete...

Page 186: ...tröme enthalten sein Nach Freischalten der Energiequelle und bevor die Arbeit am Gerät begonnen wird mindestens 1 Minute warten Einspeisung ausschließlich in das öffentliche Stromnetz Der PV Wechselrichter ist ausschließlich für die direkte Einspeisung von Wechselstrom in das öffentliche Stromnetz ausgelegt Schließen Sie keine Wechselstromgeräte an den AC Ausgang dieses Geräts an Heiße Oberflächen...

Page 187: ... Fremdeinwirkung atmosphärische Entladungen zu hohe Spannungen chemische Einflüsse normale Abnutzung und Stürze oder Beschädigungen beim Transport z Nicht fachgerecht durchgeführte Prüfungen Fehler bei Betrieb Wartung Einstellung Reparatur oder eventuelle Änderungen jeder Art die vom Hersteller des Wechselrichters nicht schriftlich genehmigt wurden z Anschluss des Wechselrichters an nicht kompatib...

Page 188: ... kontrolliert er auf der Grundlage der vom PV Generator erbrachten Leistung die Strom Amplitude Der Wechselrichter versucht immer die maximale vom PV Generator erbrachte Leistung umzuwandeln AC Anschlussbox Diese Schnittstelle zwischen dem Netz und dem PV Wechselrichter muss einen AC Schalter und die Anschlussklemmen umfassen In Übereinstimmung mit den Sicherheitsvorschriften und lokalen Sicherhei...

Page 189: ...e SIEL PV Wechselrichter Soleil wandelt den von den PV Modulen erzeugten Gleichstrom DC in Wechselstrom AC um der mit dem örtlichen Stromverteilungsnetz auch öffentliches Stromnetz bzw Verbundnetz kompatibel ist Modell Ansicht Abmessungen mm SOLEIL 3F TL10K 548 565 275 SOLEIL 3F TL15K 548 565 275 SOLEIL 3F TL20K 548 565 275 ...

Page 190: ... Kontakt zu treten installiert wurde aufbewahren Nummer des Modells und Seriennummer Das Typenschild des Wechselrichters befindet sich auf der linken Seite des Geräts Auf dem Typenschild werden der Wechselrichtertyp die Marke die Modellbezeichnung die technischen Merkmale und seine Seriennummer angegeben Sollten bei der Installation dem Betrieb des Gerätes Probleme auftreten notieren Sie bitte zue...

Page 191: ...485 Kommunikationskarte Die Benutzer können sich an den Wechselrichter anschließen und den Status und den Betrieb in Echtzeit fernüberwachen 5 Kühlkörper Dieses Gerät dient dazu die Wärme in die umliegende Umgebung abzuführen 6 USB Schnittstelle Zum direkten Anschluss eines PCs über ein USB Kabel Der Nutzer kann auf diese Weise über eine spezielle Software mit dem Wechselrichter kommunizieren 7 AC...

Page 192: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 192 von 277 FR SOLEIL 3F TL10K DE IT ES UK SOLEIL 3F TL15K DE IT ES UK SOLEIL 3F TL20K DE IT ES UK ...

Page 193: ...istung Betriebszustand und Warnhinweise Speicherzeitraum 5 Jahre Speichermedium 2GB SD Karte unterstützt bis zu 32GB Datendownload Per USB B Typ Merkmale Datenlogger mit Grafikdisplay Mehrfarbige Hintergrundbeleuchtung Die Hintergrundbeleuchtung der Display Anzeige wechselt je nach Betriebszustand des Wechselrichters die Farbe Es wird zwischen drei Farben unterschieden z Grün Hochfahren Normalzust...

Page 194: ...die Prüfung des Systems verwendet werden Normalerweise liegt die Messgenauigkeit bei 2 Die maximale Abweichung kann in allen Betriebsbereichen bei bis zu 5 liegen Die Toleranz der Messgenauigkeit kann bei allen Betriebsbedingungen zwischen 2 und 5 variieren Für den Fall dass eine präzise Messung des Systemzustands erforderlich ist müssen die notwendigen Instrumente wie z B ein Zähler installiert w...

Page 195: ...PT Ein PV Wechselrichter muss in der Lage sein von jedem PV Generator die maximale Leistung umzuwandeln Aufgrund des fortschrittlichen Designs ist dieser PV Wechselrichter in der Lage unter allen Bedingungen die maximale Leistung der PV Generatoren zu registrieren Wenn auf der Display Anzeige ein stabiler nicht schwankender Wert angezeigt wird bedeutet dies dass der Wechselrichter dabei ist die vo...

Page 196: ...den Reparatur Service auf In der Zubehör Box 3 sind folgenden Komponenten enthalten Artikel Menge Artikel Beschreibung Abbildung Bedienungsanleitung 1 Installations und Bedienungsanleitung AC Abdeckung 1 Obere Abdeckung für den AC Anschluss DC Stecker Entnahme Tool 1 Trennwerkzeug für den DC Anschluss Gummibuchse 1 Zubehör für den Anschluss der AC Drähte Nylon Dübel 6 Zur Befestigung der Montagepl...

Page 197: ...r bis zu 60 C betragen kannq Für einen optimalen Betrieb empfiehlt es sich jedoch den Wechselrichter an einem Ort zu installieren an dem die Umgebungstemperatur zwischen 0 und 45 C liegtq Hinweis Setzen Sie den PV Wechselrichter nicht der direkten Sonneneinstrahlung aus Direkte Sonneneinstrahlung erhöht die Innentemperatur die die Umwandlungseffizienz reduzieren kann Anmerkung Obwohl der Wechselri...

Page 198: ...stens 30 cm und unter dem Wechselrichter mindestens 90 cm Abstand 3 Für eine angemessene Wartung muss zwischen den Wechselrichtern ein seitlicher Abstand von mindestens 30 cm eingehalten werden Anmerkung Installieren Sie wenn möglich PV Wechselrichter nicht übereinander oder über anderen Wärmequellen Ist dies nicht möglich halten Sie einen Mindestabstand von 100 cm ein damit für ausreichende Belüf...

Page 199: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 199 von 277 FR Montagehalterung Anmerkung Der Durchmesser der Sicherungsschraube beträgt 10mm2 ...

Page 200: ...e mit geeignetem Hebewerkzeug an den Installationsort gehoben werden nachdem die Aufhänghilfen an den PV Wechselrichter geschraubt wurden wie unten dargestellt Montage des PV Wechselrichter mittels Aufhänghilfe fakultativ Anmerkung Geeignetes Hebewerkzeug muss zur Aufhängung verwendet werden ...

Page 201: ... 04 21 Seite 201 von 277 FR 6 Befestigen Sie den PV Wechselrichter wie dargestellt an der Montageplatte Montage des PV Wechselrichters an der Wand 7 Vergewissern Sie sich dass das Gerät in der richtigen Lage fest in der Halterung sitzt ...

Page 202: ... Tabelle unten angegeben Der Querschnitt der Leitungen für L1ᇬL2ᇬL3ᇬNᇬPE1 muss mindestens den Angaben in der nachstehenden Tabelle entsprechen Modell SOLEIL 3F TL10K SOLEIL 3F TL15K SOLEIL 3F TL20K Leistung W 10000 15000 20000 Max Ausgangsstrom 16 A 24 A 30A Max Querschnitt Ausgangskabel 10 AWG 8 AWG 8 AWG Anmerkung Verwenden Sie möglichst keine Leitungen mit Leitungsverlusten größer 1 Der Quersch...

Page 203: ... G fest am AC Anschluss des PV Wechselrichters angeschlossen sein bevor die AC Quelle eingeschaltet werden kann Wenn Sie die AC Versorgung vom Wechselrichter trennen müssen dann schalten Sie zuerst die DC Quelle des Wechselrichters ab Trennen Sie dann zur gleichen Zeit die AC Quelle Phase L1ᇬPhase L2ᇬPhase L3 und Phase N des PV Wechselrichters um den Wechselrichter selbst zu schützen Bei Nichtbeac...

Page 204: ...en Sie dass der Wechselrichter ordnungsgemäß montiert ist indem Sie versuchen ihn leicht von unten anzuheben und zu drehen Der Wechselrichter muss dabei fest in seiner Halterung sitzen bleiben Nach der Montage überprüfen Sie dass für die Installation ein Standort ausgewählt wurde der die freie Sicht auf die Statusanzeige ermöglicht dass die ausgewählte Montagewand robust ist damit Vibrationen währ...

Page 205: ... für den Anschluss des Wechselrichters an das öffentliche Netz Die AC Anschlussbox muss von einer qualifizierten Fachkraft in Übereinstimmung mit den lokalen Sicherheitsvorschriften ausgelegt werden Modell SOLEIL 3F TL10K SOLEIL 3F TL15K SOLEIL 3F TL20K Max Ausgangsstrom 16A 24A 30A Externe nominale Schutzart gegen Überströme 20A 25A 35A Achtung Eine geeignete Schutzeinrichtung gegen Überströme fü...

Page 206: ...F TL20K 1000V 34 5A 2 Achtung Einen externen DC Stecker Leitung Verbinder auswählen der für einen Nennstrom ausgelegt ist der über dem maximalen Eingangsstrom des Wechselrichters liegt Achtung Die PV Generatoren mit einem Kurzschlussstrom auswählen der kleiner als der maximale Eingangsstrom des Wechselrichters ist 9Stets den positiven Pol der PV Module an den positiven Eingangspol des Wechselricht...

Page 207: ...erkung Lassen Sie sich von Ihrem Händler bei der Auswahl des PV Moduls beraten Anforderungen des PV Moduls Für den Anschluss an den DC Eingang eines einzigen Wechselrichters sollten die angeschlossenen Strings aus Modulen des gleichen Typs bestehen Der DC Anschluss im Eingang darf nicht mit anderen Wechselrichtern geteilt werden Die Anzahl Ausrichtung und Neigung der Generatoren kann in Abhängigke...

Page 208: ...V351 Rev04 Ausstellungsdatum 2015 04 21 Seite 208 von 277 FR Die folgende Tabelle listet diese Stecker Paare MultiContact Amphenol PV KST4 6I Buchse Helios H4 Buchse PV KBT4 6I Stecker Helios H4 Stecker ...

Page 209: ...l DC Stecker mit der mit dem Entnahme Tool das in der Zubehör Box zusammen mit dem Wechselrichter geliefert wird getrennt werden können 1 Setzen Sie das Entnahme Tool wie in folgender Abbildung am Stecker an um die Klemmen zu lösen 2 Nachdem Sie die Klemmen gelöst haben ziehen Sie den Stecker leicht nach unten um die DC Leitung zu entfernen ...

Page 210: ... kann das Gerät dauerhaft beschädigen 5 8 Post Inbetriebnahme 9 Wenn der Generator ausreichender Lichteinstrahlung ausgesetzt wird liegt Hochspannung an An den ausgesetzten Anschlussklemmen des PV Generators liegt Spannung an sie können zu Stromschlägen führen Vermeiden Sie es mit diesen Teilen der Vorrichtung in Berührung zu kommen 9 Nach Anschluss des PV Generators an den Wechselrichter beträgt ...

Page 211: ...ewissern Sie sich dass die AC Leistung getrennt wurde bevor Sie den DC Schalter falls vorhanden ausschalten Trennen Sie zuletzt die DC Leitungen Hinweis Stellen Sie sicher dass die AC Spannung niemals außerhalb der Produktspezifikationen liegt Achtung Verwenden Sie ein Vielfachmessgerät und überprüfen Sie die Polarität aller DC Eingangspaare auf ihre Richtigkeit bevor sie die DC Leistung des Wechs...

Page 212: ...ung der Ländereinstellung 9 Bei der ersten Inbetriebnahme aktiviert der Wechselrichter die Funktion Select Safety Mit diesem Prozess ist es möglich die Sprache der Anzeige und die Ländereinstellung auszuwählen bevor mit dem normalen Betrieb begonnen wird 9 Solange die Ländereinstellung am Wechselrichter nicht abgeschlossen ist kann dieser nicht normal betrieben werden auch wenn er ordnungsgemäß an...

Page 213: ...ntsprechenden Text mit dazugehöriger Farbe 1 Normal In diesem Betriebszustand wandelt der Wechselrichter ohne Unterbrechung den Strom um der vom Solargenerator ins öffentliche Netz gespeist wird In diesem Fall ist die Display Anzeige grün 2 Rückstellung nach einem Fehler In bestimmten Situationen beispielsweise bei anormaler Spannung und Frequenz kommt es vor dass der Wechselrichter vom Netz getre...

Page 214: ...chtung wird rot und ein Warnsignal macht den Benutzer auf die Störung aufmerksam Um die Fehlermeldung vom Display zu entfernen kann der Benutzer auf den Navigationstasten die OK Taste drücken um die Fehlermeldung zurückzusetzen Lesen dazu bitte erst die Meldung Kann die Fehlermeldung nicht beseitigt werden wenden Sie sich bitte an das Service Center vor Ort No Utility Press OK to Clear 4 Abschalte...

Page 215: ...et sich der Wechselrichter auf DC Seite im Warten Zustand Dabei prüft der Wechselrichter die DC und die AC Seite und wartet auf die Zuschaltung zum AC Netz Pac 0W Vdc 260 329V Vac 219 4 219 3 219 3V Temperature 26 8 C Status Waiting 21 04 12 15 01 z Normal Um in den Normal Betrieb zu gelangen muss die DC Spannung mehr als 350 VDC betragen Um die Anschlüsse der DC Leitungen zu überprüfen versucht d...

Page 216: ...ndbeleuchtung je nach Betriebszustand Um Strom zu sparen bleibt die Hintergrundbeleuchtung nach jedem Bedienvorgang nur 3 Minuten an Tritt jedoch ein Fehler auf leuchtet der Hintergrund der Anzeige nicht nur rot sondern blinkt solange im Sekundentakt auf bis der Benutzer die auf dem Display angewiesene Taste drückt 3 Akustisches Signal Der Datenlogger generiert ein akustisches Signal um den Benutz...

Page 217: ...atum und Uhrzeit zu sehen Tritt eine Warn oder Fehlermeldung auf wird die Statusanzeige in der letzten Zeile durch diese Fehlermeldung ersetzt Der Benutzer kann die vier Messwerte verändern z Drücken Sie Z um den Messwert in der ersten Zeile zu markieren Mit den Tasten und kann der Benutzer in die nächste Zeile wechseln z Drücken Simeon um mit dem Einstellen der Messwerte zu beginnen z Drücken Sie...

Page 218: ...der Punkt stellt einen in einem Zeitraum von 6 Minuten gemittelten Wert dar Jeder Punkt stellt 500W dar es können maximal 48 Punkte dargestellt werden z Datum Rechts oben ist das Datum der aktuellen Anzeige zu sehen Um zum Tagesdiagramm eines bestimmten Tages zu gelangen drücken Sie zur Auswahl auf die Tasten Z und Y 6 12 9 7 8 10 11 1 2 3 4 5 20 KW 20 04 ź ź 10 4 Wochendiagramm Wenn Sie in der Ta...

Page 219: ...Fehlergeschichte erscheinen auf der LCD Anzeige Systeminformationen zum Wechselrichter Dazu gehören beispielsweise die Seriennummer und die Firmware Version etc wie unten dargestellt System Display S N 0123456789ABCDEF Version MB 20 00 27 Memory 0 3 Date 21 04 2011 Sat Time 15 01 19 GMT 08 Audible Alarm On Language English Nachfolgend sehen Sie die Kontrollparameter die in den Systeminformationen ...

Page 220: ...auf bzw um den Parameter zu den gewünschten Einstellungen zu ändern b Drücken Sie OK um die Einstellung zu bestätigen Drücken Sie auf die Tasten und um den Wert zu verändern c Drücken Sie OK um die Einstellung zu bestätigen d Drücken Sie Y um die Auswahl abzubrechen und die Einstellung abzuschließen ...

Page 221: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 221 von 277 FR Funktionsschema des Datenloggers ...

Page 222: ...ieren Für gewöhnlich werden folgende Einstellungen verwendet 100 60 30 0 7 1 2 Frequenzabhängige Wirkleistungsbegrenzung Das Prinzip dieser Anforderung besteht darin die überschüssige Leistungserbringung durch eine Erhöhung der Netzfrequenz zu erkennen Die frequenzabhängige Wirkleistungsbegrenzung löst eine schnelle Reaktion in Abhängigkeit der plötzlichen Veränderungen der Netzfrequenz aus Wenn d...

Page 223: ...etzte Weise Der Wechselrichter 2G3P unterstützt vier Formen der Blindleistung die vom Netzbetreiber für seine Anlage verwendet werden können Die Sollwert Kontrolle oder die Kennlinie lassen sich über die Kommunikationsmöglichkeit einstellen Im Folgenden werden die einzelnen Methoden beschrieben 7 2 1 COSij Sollwert Kontrolle Der Betreiber weist einen festen Wert für den Leistungsfaktor Cosij innerha...

Page 224: ...ten Wert der Blindleistung Q zu mit einem zulässigen Einstellungsbereich Q 6kVar bis 6kVar beim 10kW Modell Die Wirkleistung im Ausgang der Q Sollwert Kontrolle kann folgendermaßen dargestellt werden Der grüne Bereich zeigt den zulässigen Betriebspunkt z B beim 10 kWh Modell b Ausgangsblindleistung der Setpoint Kontrolle Q ...

Page 225: ...ine andere Kurve bereitstellen Die vorgegebene Kennlinie COSij P verfügt über 4 Arbeitspunkte und einen werkseitig eingestellten Grenzwert cosij Der zulässige Bereich des Grenzwerts cosij liegt zwischen 0 8 1 0 und für die Arbeitspunkte zwischen 0 100 d Werkseitig eingestellte Kennlinie COSij P Die Wirkleistung im Ausgang der Kennlinie COSij P kann folgendermaßen dargestellt werden Der grüne Bereich ze...

Page 226: ...en jedoch eine andere Kurve bereitstellen Die vorgeschriebene Kennlinie Q U verfügt über vier Arbeitspunkte und einen werkseitig eingestellten Grenzwert Q Der zulässige Bereich des Grenzwerts Q S liegt zwischen 0 60 und für die Arbeitspunkte zwischen 0 100 f Die werkseitig eingestellte Kennlinie Q U Die Wirkleistung im Ausgang der Kennlinie Q U kann folgendermaßen dargestellt werden Der grüne Bere...

Page 227: ...hselrichter wurde entwickelt um benutzerfreundlich zu sein Alle Betriebszustände werden in klar verständlicher Weise auf dem Display oder über Fernüberwachung angezeigt Alle möglichen Meldungen werden in der folgenden Tabelle aufgeführt Matrix der Sprachen der angezeigten Meldungen Fortsetzung nächste Seite ...

Page 228: ...emoria xx x Memoria xx x Carte SD xx x Geheugen xx x Datums angabe Date dd mm yyyy Sun Datum dd mm yyyy So Fecha dd mm yyyy Dom Data dd mm yyyy Dom Date dd mm yyyy dim Datum dd mm yyyy Zo Date dd mm yyyy Mon Datum dd mm yyyy Mo Fecha dd mm yyyy Lun Data dd mm yyyy Lun Date dd mm yyyy lun Datum dd mm yyyy Ma Date dd mm yyyy Tue Datum dd mm yyyy Di Fecha dd mm yyyy Mar Data dd mm yyyy Mar Date dd mm...

Page 229: ...ñol Spagnolo Espagnol Spaans Anzeige in italienisch Italy Italienisch Italiano Italiano Italien Italiaans Anzeige in Französisch France Französisch Frances Francese Français Frans Anzeige in holländisch Dutch Holländisch Holandés Olandese Hollandaise Nederlands Informationsmeldungen Zähler Informationsmeldungen Zähler Betriebszusta nd ENGLISH DEUTSCH Deutschland ESPAÑOL Spanien ITALIANO Français F...

Page 230: ... fonction xxxxxxhr h Totaal xxxxxxhr Innentemperatur Temperature xx xºC Temperatur xx xºC Temperatura xx xºC Temperatura xx xºC Température xx xºC Temperatuur xx xºC Netzspannung Vac xxx x xxx x xxx xV Uac xxx x xxx x xxx xV Vac xxx x xxx x xxx xV Vac xxx x xxx x xxx xV VAC xxx x xxx x xxx xV Uac xxx x xxx x xxx xV Netzfrequenz Frequency xx xHz Frequenz xx xHz Frecuencia xx xHz Frequenza xx xHz Fr...

Page 231: ...Stato In attesa Etat Prêt Status Wachten Netzüberwachung mit DC Spannung 350V Status Checking xxxs Status Netz Prüf xxxs Estado Chequeo xxxs Stato Test xxxs Etat Vérif xxxs Status Controle xxxs Wechselrichter speist ins Netz Status Normal Status Normal Estado Normal Stato Normale Etat Connecté réseau Status Normaal Störung an der Anlage oder am Wechselrichter Status Fault Status Fehler Estado Defe...

Page 232: ... Netzfrq Def frec red Err Freq rete Déf Freq réseau Netfreq fout Isolationsfehler am PV Generator Isolation Fault Isolationsfehler Def aislamiento Err Isolamento Défaut isolation Isolatiefout AC Netz nicht verfügbar No Utility Kein Netz Red ausente Rete assente Réseau absent Net niet aanw Netzüberspannung PV over voltage DC Überspannung Sobretensión DC Sovratensione DC Surtention DC DC overspannin...

Page 233: ...US Low DC Bus DC Bus zu tief Bus DC bajo DC Bus basso Entrée 1 faible DC bus laag Zu hohe Spannung an DC BUS High DC Bus DC Bus zu hoch Bus DC alto DC Bus alto Entrée 1 élevée DC bus hoog Messung zwischen CPU Master und Slave nicht konsistent Consistent Fault Konsistenzfehler Defec Coherencia Err processore Err processeur CPU fout Firmware Version DSP und CPU Slave sind nicht kompatibel M S Ver Fa...

Page 234: ...V Generator unmöglich PV Connect Fault PV Verbdg fehler Defecto conex PV Err conness PV Err Connect PV PV verbind fout Fehler beim IGBT Start Inv Start Fault Inv Start Fault Def arranque Inv Err attivazione Déf Démarrage Inv Start Fault Interner Lüfter funktioniert nicht Internal Fan Lock Lüfter blockiert Bloq vent Intern Ventil int blocc Verr Ventil Int Int vent geblokk Externer Lüfter funktionie...

Page 235: ...Deutschland ESPAÑOL Spanien ITALIANO Français France Nederlands Dutch Allgemeine System Log Meldungen Press OK to Clear OK um zu Löschen Borrar Pulse OK Premi OK x reset OK suppression Druk OK om te wissen No Daily Records Keine Tagesaufzeichng Dia No registro NO Dati giorno Pas aff jour Geen dagrecords No Weekly Records Keine Wochenaufzeichn Sem NoRegistro NO Dati settim Pas aff semaine Geen week...

Page 236: ...eichnen Auch die Firmware wird über diese Schnittstelle aktualisiert Anschluss eines Notebooks an den Wechselrichter via USB Typ A auf Typ B Adapterkabel 9 2 Kommunikationssteckplatz RS 485 Der PV Wechselrichter verfügt über einen Steckplatz für optional erhältliche Kommunikationsschnittstellen Durch die Installation einer RS 485 Karte oder einer kompatiblen Karte kann die Kommunikationsfähigkeit ...

Page 237: ...mäß montiert und installiert werden um die Dichtigkeit des Gerätes zu gewährleisten Die RS485 Karte verfügt über zwei RJ45 Ports mit LEDs einen Klemmblock für die Anschlüsse und einen DIP Schalter mit Abschlusswiderstand für den Kommunikationsbus wie in der Zeichnung oben dargestellt Die PWR Leistung LED zeigt an dass die RS485 Karte angeschlossen ist Sie leuchtet grün wenn die RS485 Karte vom Wec...

Page 238: ... von 2Hz blinkt Die folgende Tabelle zeigt die Pin Belegung der RJ45 Ports der RS485 Karte RS485 Verdrahtungsinformation Am Stecker liegt DC Spannung an Pin 7 und Pin 8 des RJ45 Ports werden für die DC Versorgung verwandt Stellen Sie sicher dass keine anderen Geräte an diesen Port angeschlossen sind um Schäden zu vermeiden PIN BEZEICHNUNG Spannung 1 Tx s400mVp p s15Vp p 2 Tx 3 Rx 400mVp p 15Vp p 4...

Page 239: ...rbindung der RS485 Karte Es ist möglich alleRJ45 Ports auf jeder RS485 Karte mit einer Ethernet Leitung anzuschließen Dabei muss es sich um eine Leitung des Typs Straight Through handeln Verbindung über Ethernet Leitung Typ A für RS485 Karte Anschluss über Ethernet Leitung Typ B für RS485 Karte ...

Page 240: ...85 Karte wie in der Abbildung unten gezeigt wird Als Terminierungen der RS485 Karte werden Leitungen mit verdrillten Paaren twisted pair verwendet Kabelverbindungen mit verdrillten Paaren twisted pair für RS485 Karte Als Standard Verbindung für die RS485 Karte können die Leitung mit verdrillten Paaren twisted pair und die Ethernet Leitung auch kombiniert verwendet werden wie in der Abbildung unten...

Page 241: ...lossen d h der Empfänger wird an den Sender und der Sender an den Empfänger angeschlossen Weitere Details unten Abschlusswiderstände über DIP Schalter Der DIP Schalter kann zur Konfiguration der RS485 Karte des letzten Wechselrichters auf derselben Linie als Abschlusswiderstand der Kommunikation verwendet werden DIP switch ein Ein Auszustand des DIP Schalters Pin2 Pin 1 Pin 1 Pin 2 ...

Page 242: ...DIP Schalters auf ON gestellt werden wird auf der RS385 Karte des letzten Wechselrichters der Abschlusswiderstand aktiviert Diese Konfiguration ist nur für den letzten Wechselrichter erforderlich Belassen Sie die DIP Schalter der anderen Wechselrichter auf Off 9 4 Spezifikation RS485 Karte ...

Page 243: ... ob die Kabel für die ordnungsgemäße Übertragung zu lang sind Die Gesamtlänge sollte kleiner 800m sein Überprüfen Sie ob die Umgebungstemperatur innerhalb von 10 C bis 70 C liegt Modbus Karte INSTALLATION UND ANSCHLUSS Die PCB SERMB Karte ist ein Zubehör der PV Wechselrichter Die Installation darf nur bei abgeschaltetem OFF Wechselrichter durchgeführt werden Installieren Sie die Karte nicht wenn d...

Page 244: ...werden i Die Karte in den entsprechenden Steckplatz einfügen und die Schutzabdeckung die mit dem PV Wechselrichter geliefert wird so befestigen dass das Gerät vor Wassereintritt geschützt ist i Den PV Wechselrichter einschalten und die MODBUS Karte prüfen ig 1 RS 485 RS422 Anschlüsse 1 Die Verbindung des Erdleiters trägt dazu bei Offset Probleme zwischen den verschiedenen Geräten zu beseitigen Er ...

Page 245: ...600 3 Reserviert DIP8 1 2 3 4 5 6 7 8 ON DIP ID Funktion DIP Beschreibung 4 Protokoll Auswahl DIP1 2 1 2 3 4 DIP DIP 2 DIP1 PROTOKOLL OFF OFF Modbus Funktion OFF ON ON OFF ON ON 5 Ladung RS485A DIP3 1 2 3 4 DIP ON DIP 3 OFF No DIP 3 ON 120Ohm 6 Ladung RS485B DIP4 1 2 3 4 DIP ON DIP 4 OFF No DIP 4 ON 120Ohm LED GELBE LED Modbus Kommunikation GRÜNE LED Interner Status Aus OFF Keine Kommunikation mit...

Page 246: ...scher Anschluss an die Modbus Linie Falsche Einstellung der Parameter Den Anschluss prüfen Die Einstellungen zu den Abschlusswiderständen prüfen Die Einstellungen der DIP SCHALTER prüfen TECHNISCHE EIGENSCHAFTEN In der Tabelle unten werden die technischen Eigenschaften der Modbus Schnittstellenkarte aufgeführt Eigenschaft Spezifikation Spannung 12VDC Beschreibung Umwandlungskarte Modbus Protokoll ...

Page 247: ...llungsdatum 2015 04 21 Seite 247 von 277 FR 9 6 USB Schnittstelle Datenlogger Der Datenlogger ist zur Verbindung an einen PC mit einer USB Typ B Schnittstelle ausgerüstet Entfernen Sie zuerst die Abdeckung der USB Buchse ...

Page 248: ...el 6537 6537VAR 20k model 8717 8717VAR 0 90 0 90pf Type A B P lock in 10 100 P lock out 5 Node X axis 80 120 Node Y axis 43 6 43 6 V lock in 230 0 253 0V V lock out 207 0 230 0V Node X axis 0 100 Node Y axis 0 90 0 90pf OK OK OK OK OK Reactive Power Func Mode Off Value N A Press OK over 5s to change the setting Reactive Power Func Mode Const Q Value 1000VAR Press OK over 5s to change the setting R...

Page 249: ... Vista Windows 7 wird kein zusätzlicher Treiber benötigt Für Windows 98 wird ein zusätzlicher Treiber für den Zugriff auf den Datenlogger benötigt 2 Verbinden Sie das USB Adapter Kabel mit einem PC Die LED zeigt USB ANGESCHLOSSEN wenn der Datenlogger mit einem PC verbunden ist 3 Klicken Sie auf Computer und dann Wechseldatenträger Disk auf Ihrem PC 4 Kopieren Sie den DAILY Ordner im Wechseldatentr...

Page 250: ...21 Seite 250 von 277 FR 6 Wählen Sie Datum von und Datum bis zum Festlegen des gewünschten Zeitraums Klicken Sie anschließend auf Import 7 Wählen Sie in Ihrem bereits gespeicherten Ordner die Datei DAILY dat aus Klicken Sie dann auf Öffnen ...

Page 251: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 251 von 277 FR ...

Page 252: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 252 von 277 FR 8 Klicken Sie nun auf Ansicht Die gespeicherten Daten werden von der Software verarbeitet 9 Klicken Sie auf Export ...

Page 253: ...ie Daten werden dann in dem von Ihnen bevorzugten Dateiverzeichnis auf Ihrem PC im CSV Format gespeichert 11 Klicken Sie auf OK 12 Klicken Sie in Ihrem bevorzugten Dateiverzeichnis auf dem PC die DAILY CSV Datei doppelt an Danach können Sie die gespeicherten Daten mit Microsoft Excel verwalten ...

Page 254: ...e AC und DC Leitungen und die Isolierung 4 Schließen Sie den DC und AC Anschluss wieder an und überprüfen Sie den Betriebszustand des Wechselrichters 5 Besteht das Problem weiterhin aktualisieren Sie die Firmware laut Anweisungen oder tauschen Sie den Wechselrichter aus Anmerkung Isolationshandschuhe sollten während des Verfahrens getragen werden Isolationsfehl er Der vom Wechselrichter erkannte E...

Page 255: ...en Überprüfung senden Sie die Daten an Fachpersonal 9 Wenden Sie sich zur Überprüfung der Netzqualität an Ihren Energieversorger 10 Bitten Sie Ihren Installateur um Unterstützung 1 Trennen Sie kurzzeitig den Netzanschluss über den AC Schalter und prüfen Sie ob der Wechselrichter nach erneutem Zuschalten wieder normal arbeitet 2 Besteht das Problem weiterhin überprüfen Sie die WR Messwerte am Displ...

Page 256: ...er Anlage den Wert von 55 qC nicht übersteigt 2 Überprüfen Sie die Umgebung des Kühlkörpers 3 Entfernen Sie jedes Hindernis das die Wärmeableitung um den Kühlkörper blockiert 4 Besteht der Fehler weiterhin wenden Sie sich an den Kundendienst 1 Stellen Sie sicher dass die Umgebungstemperatur der Anlage den Wert von 55 qC nicht übersteigt 2 Überprüfen Sie den Installationsort Der WR sollte nicht dir...

Page 257: ...inks beschrieben vor 2 Besteht der Fehler weiterhin aktualisieren Sie die Firmware laut Anweisungen oder tauschen Sie den Wechselrichter aus Bus DC zu hoch Die DC Spannung des DC BUS im Innern des Inverters ist höher als vorgesehen Die DC Eingangsspannung die den DC BUS versorgt ist zu hoch 1 Trennen Sie alle PV und PV vom Eingang und fahren Sie das Gerät erneut hoch 2 In diesem Fall wenden Sie si...

Page 258: ...er Einstrahlung kann der PV Wechselrichter ständig neu starten und abschalten Die erzeugte Energie ist in diesem Fall für den Betrieb der Steuerelektronik nicht ausreichend Achtung An den DC und AC Leitungen und Anschlüssen liegen gefährlich hohe Spannungen an Berühren Sie KEINE spannungsführenden Teile ...

Page 259: ...es Kühlkörpers um sicherzustellen dass der Luftstrom nicht behindert wird 9 Überprüfung auf mögliche Korrosion insbesondere an Verbindungspunkten 9 Alle Verbindungen sollten regelmäßig auf Festigkeit überprüft werden 9 Reinigen Sie die Oberflächen des Geräts regelmäßig mit einem feuchten Tuch um es von Staub und Verschmutzungen zu befreien Das Garantieschild in einwandfreiem Zustand halten 9 Um op...

Page 260: ...erst von den AC und DC Quellen frei 2 Lösen Sie alle Schrauben des Lüfter Moduls wie in der Abbildung unten angeben 3 Entnehmen Sie das Lüfter Modul durch Trennen des Steckers wie in der Abbildung unten angegeben 4 Falls erforderlich reinigen Sie die Lüfter vorsichtig mit einem feuchten Tuch oder einer weichen Bürste 5 Wenn der Lüfter beschädigt ist ersetzen Sie ihn durch einen neuen 6 Bringen Sie...

Page 261: ...ten angeben 3 Entnehmen Sie das Lüfter Modul durch Trennen des Steckers wie in der Abbildung unten angegeben 4 Falls erforderlich reinigen Sie die Lüfter vorsichtig mit einem feuchten Tuch oder einer weichen Bürste 5 Wenn der Lüfter beschädigt ist ersetzen Sie ihn durch einen neuen 6 Bringen Sie die abgenommenen Lüfterkomponenten in umgekehrter Reihenfolge wieder an 7 Überprüfen Sie den Wechselric...

Page 262: ...ten angeben 3 Entnehmen Sie das Lüfter Modul durch Trennen des Steckers wie in der Abbildung unten angegeben 4 Falls erforderlich reinigen Sie die Lüfter vorsichtig mit einem feuchten Tuch oder einer weichen Bürste 5 Wenn der Lüfter beschädigt ist ersetzen Sie ihn durch einen neuen 6 Bringen Sie die abgenommenen Lüfterkomponenten in umgekehrter Reihenfolge wieder an 7 Überprüfen Sie den Wechselric...

Page 263: ...ng DC DC Nennspannung 720 V Max PV Leerlaufspannung 1000V Anlagenspannung beim Hochfahren 260V Einschaltspannung 350 V Ausschaltspannung In der Regel 200V Betriebsspannungsbereich 250 1000V Nennspannungsbereich MPPT 350 850 V 400 850 V 450 850 V MPPT Wirkungsgrad 99 Anzahl MPP Tracker 2 Max DC Leistung 10500W 15750W 21000W Max Eingangsstrom 16A 2 20A 2 23A 2 Max Anzahl Parallelstrings 2 2 2 2 3 2 ...

Page 264: ...z nach der landesspezifischen Konfiguration siehe 12 3 Klirrfaktor Ausgangsstrom THD i 4 3 Phasenverschiebung cos bei Nennausgangsleistung einstellbar 0 99 0 8 auf Anfrage Wirkungsgrad Max Umwandlungswirkungsgrad ฺ97 8 ฺ97 7 ฺ97 7 Euro Wirkungsgrad ฺ97 2 ฺ97 0 ฺ97 2 Allgemeine Daten Topologie Transformerlos Leistungsaufnahme Standby Nachts ู 20W ู 1W ู 20W ู 1W ู 20W ู 1W Schutzgrad Außen Chassis ...

Page 265: ...alter durch die Norm EN IEC zugelassen Kommunikation Standard USB Typ B RS485 optional RS485 Super 485 Modbus RS485 Protokoll Frontrahmen Datenlogger Anzeige 128 64 Pixel Funktionstasten 5 Standard integriert Optional abnehmbar Bezugsnormen Norm für Netzschnittstelle VDE AR N 4105 VDE0126 1 1 A1 VDE0126 1 1 RD1699 G83 1 1 G59 Issue 2 CEI0 21 Sicherheit IEC 62109 1 2010 EN 62109 1 2010 IEC 62109 2 ...

Page 266: ...Leistungsfaktor 0 9 Verzögerung Voreilung 0 99 Spannungstoleranz besser als 1 N A Frequenztoleranz besser als 0 1 N A Betriebsfrequenzbereich 1 47 5 51 5Hz Abschaltung innerhalb von 0 2 Sekunden 2 Punkt Rückfrequenz Wie die rote Linie vor der Abschaltung Werkseinstellung Frequenzwert 47 5 Hz 51 5Hz 47 55 Hz 51 45Hz Wiederanschlusszeit 1 60s 85 110 Volt 47 5Hz 50 05Hz mit 10 Stromzunahme min PV Ein...

Page 267: ...chreitung des Betriebsspannungsbereichs 15 10 15 1 5 Sekunden 1 5 Sekunden 0 2 Sekunden Einstellung der Spannungswerte in der Firmware 198V 250V 262V Betriebsfrequenzbereich 48Hz 50 5Hz 3 Sekunden 0 5 Sekunden Wiederanschluss 50Hz wenn Überfrequenz Einstellung der Frequenzwerte in der Firmware 48 05 Hz 50 45 Hz Wiedereinschaltzeit NA Wiedereinschaltzeit PV Einstellung 180 Sekunden Abschaltzeit bei...

Page 268: ...nspeisung 20mA 0 25 des AC Nennstroms Modell SOLEIL 3F TL10K SOLEIL 3F TL15K SOLEIL 3F TL20K Bezugsnorm Netzwerkdienst VDE 0126 1 1 Grenzwert für die einzelne Phase NA Betriebsspannungsbereich 230V 400V 20 15 Abschaltzeit bei Überschreitung des Betriebsspannungsbereichs 0 2 secondi 10 minuti Werkseinstellung Spannung 187V 262V 250V Frequenztoleranz 47 5 50 2Hz Abschaltung innerhalb von 0 2 Sekunde...

Page 269: ...2s Frequenz S2 47 0 50 0Hz 50 0 52 0Hz Werkseinstellung Frequenz S2 47Hz 51Hz Abschaltzeit S2 F 00 10 5 00S 00 10 5 00S Werkseinstellung Abschaltzeit S2F 4s 1s Grenzleistungskurve P als Funktion der Netzüberfrequenz Statik 2 5 einstellbar 2 4 Default Wert kann aus oder eingeschaltet werden Wartezeit vor Wiederanschluss wartet 300 s mit Frequenz innerhalb des korrigierten Bereichs für Frequenzwert ...

Page 270: ...ar 8717 Var 48 43 P 2 Const PF Ͳ 0 90 0 90 pf 3 Kennlinie Q U mit Typ A B P Lock in 20 Pn P Lock out 5 Pn Knoten1 90 43 6 Q S Knoten2 92 0 Q S Knotent3 108 0 Q S Knoten4 110 43 6 Q S 4 Kennlinie PF P Typ A V Lock in 241 5 V V Lock out 230 0 V Knoten1 20 1 00pf Knoten2 40 1 00pf Knotent3 50 1 00pf Knoten4 90 0 90pf Kennlinie PF P Type B Knoten1 0 1 00pf Knoten2 5 1 00pf Knoten3 5 0 90pf Knoten4 90 ...

Page 271: ...pannungs und Frequenzbereiche und die Abschaltzeiten einstellbar S1 Mittlerer Spannungswert in einem Zeitfenster von 10 Minuten 3 Der Wechselrichter wird hochgefahren wenn die Frequenz und Spannungswerte zwischen 49 9 50 1Hz und 195 5 253V einschließlich der ersten Inbetriebnahme liegen ...

Page 272: ... an den Hersteller wenden Der Wechselrichter darf unter keinen Umständen mit dem Haushaltsabfall entsorgt werden Die Entsorgung des PV Wechselrichters nach Ende der Nutzungsdauer muss gemäß den zu diesem Zeitpunkt am Installationsort geltenden Bestimmungen zur Entsorgung von Elektronik Altgeräten erfolgen Anmerkung Anweisungen zur fachgerechten Entsorgung erhalten Sie vom Wiederverkäufer ...

Page 273: ...blemen bezüglich dieses Produkts wenden Sie sich bitte an unsere Service Hotline Um Ihnen den notwendigen Service bieten zu können benötigen wir folgende Informationen Typ des Wechselrichters Seriennummer des Wechselrichters Typ und Anzahl der angeschlossenen PV Generatoren Fehlermeldung Kommunikationsart ...

Page 274: ...e Belastungsdiagramme sind normale Wirkungsgraddiagramme bezogen auf VDC und PAC und die Ausgangsleistung im Betriebsbereich kann durch die unterschiedlichen Stufen der Eingangsspannung als Leistungskurve bestimmt werden wie unten dargestellt Modell Leistungskurve SOLEIL 3F TL10K SOLEIL 3F TL15K SOLEIL 3F TL20K ...

Page 275: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 275 von 277 FR 17 2 Wirkungsgradkurve ...

Page 276: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 276 von 277 FR ...

Page 277: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 277 von 277 FR SIEL S P A VIA 1 MAGGIO 25 20060 TREZZANO ROSA MILANO ITALIA TEL 39 02 90986 1 FAX 39 02 90968490 INFO SIELUPS COM WWW SIELUPS COM ...

Reviews: