![SICK ZIRKOR Series Operating Instructions Manual Download Page 73](http://html.mh-extra.com/html/sick/zirkor-series/zirkor-series_operating-instructions-manual_1264209073.webp)
73
8024252/AE00/V1-0/2020-07| SICK
O P E R A T I N G I N S T R U C T I O N S | ZIRKOR200 Ex-D
Subject to change without notice
DECOMMISSIONING
12
12
Decommissioning
12.1
Safety information on decommissioning
Technical knowledge needed / requirements for decommissioning
Danger of explosion
Gas
Electricity
Observe all safety information in the Commissioning and Electrical Installation Sections:
see “Electrical installation”, page 31
Note:
●
You are basically familiar with the ZIRKOR200 Ex-D.
●
You are basically familiar with the ATEX Directive.
●
You are familiar with the local situation, especially the potential hazards caused by
gases in the gas duct (hot/noxious). You are capable of recognizing and preventing
danger by possibly escaping gases.
If one of these requirements is not met:
▸
Please contact SICK Customer Service or your local representative.
DANGER:
Danger of explosion through residual voltages and hot surfaces in the device
After switching off the device, there is a danger of explosion due to the residual voltage
and hot surfaces.
▸
Only perform work on the device in an Ex-free environmant.
DANGER: Health hazard due to contaminated probe
Depending on the composition of the gas in the measuring channel, the measuring
probe, after use in the process, may be contaminated with substances that can cause
serious damage to health.
▸
Wear protective clothing in accordance with regulations when working with a
contaminated measuring probe.
▸
Decontaminate the measuring probe before storage.
WARNING:
Danger to health from contact with hot and/or aggressive measuring gases
There is a risk of contact with noxious sample gases when working on an open
measuring duct.
▸
Observe the valid regulations concerning protective equipment during operation
during all work on the device.
▸
Never remove the probe from the duct in case of overpressure in the duct without
taking appropriate safety precautions.