O P E R A T I N G I N S T R U C T I O N S | ZIRKOR200 Ex-D
Subject to change without notice
5
INSTALLATION
5.9.8
Installing the probe cable
WARNING: Danger of explosion
●
Disconnect the power voltage from the system before removing the terminal cover.
First connect the power voltage supply to the system again after attaching the
terminal cover.
●
Live parts may not be accessible after installation. Do not
Note:
Connect the probe cable shielding in the electronics housing on one side to the
protective conductor (PE terminal).Never connect the probe cable shielding to the probe,
otherwise the measured value will be distorted.
The probe cable is suitable for an ambient temperature of -40 °C to + 90 °C.
The probe cable may only be installed at temperatures in the range of -5 °C to +50 °C.
Observe maximum possible cable length (max. pump version cable length - 50 m).
Observe minimum bending radius.
R
min
= 330 mm
Lay probe cable (1) only crosswise to cables (2)
carrying the load current.
Ambient temperature limits - Installation
Ambient temperature limits - Operation