![SICK TIM3xx Technical Information Download Page 31](http://html.mh-extra.com/html/sick/tim3xx/tim3xx_technical-information_1264659031.webp)
Technical Information
Chapter
4
TiM3xx
Electrical installation
8014318/YK97/2015-04-27
© SICK AG · Germany · All rights reserved · Subject to change without notice
31
4.6.4
Wiring the switching inputs in the CDB730-001
6
1
10
5
11
15
Wiring the “IN 1 ... IN 4” switching inputs of the TiM3xx in the CDB730-001 connection module
Scheme:
TiM3xx
CDB730-001
V
S
V
S
GND
INGND
3.32 K
6.64 K
IN 1
V
in
U
IN
* = DC 9 ... 28 V
8
15
1
5
12
SGND
6
Shield
11
U
IN
*
33
IN 1
U
IN
*
GND
S3
ON
OFF
S3 : SGND-GND
Shield
D Sub HD
plug, 15-pin
GND
.
.
.
V
in
= max. 32 V
Pin and wire color assignment of prefabricated cables
D Sub HD
socket,
15-pin
1
8
9
10
11
5
Signal
V
S
IN 1
IN 2
IN 3
IN 4
GND
Cable no. 2043413
Open end,
15 cores
Red
Turquoise or light blue
Green
Gray
Pink
Black
Ratings for “IN 1 ... IN 4” switching inputs
*) INGND of the “IN 1 ... IN 4” switching inputs switched to GND of TiM3xx. Not changeable!
*)
IN 2
9
43
IN 2
IN 3
10
30
IN 3
IN 4
11
31
IN 4
Control element
supplied via
CDB730-001
Control element
supplied externally
GND
V
S ext
Power fed to an input in combination with
the other inputs starts the assigned field
set as evaluation case.
Default settings: active high level,
debouncing 10 ms
– Reverse polarity protected
– Can be wired with the PNP output of a
sensor or with a mechanical switch
Low: V
in
≤ 2 V; I
in
≤ 0.3 mA
High: 8 V ≤ V
in
≤ 32 V;
0.7 mA ≤ I
in
≤ 5 mA
Switching
behavior
Features
Electrical
values