![SICK TIM3xx Technical Information Download Page 15](http://html.mh-extra.com/html/sick/tim3xx/tim3xx_technical-information_1264659015.webp)
Technical Information
Chapter
3
TiM3xx
Mounting
8014318/YK97/2015-04-27
© SICK AG · Germany · All rights reserved · Subject to change without notice
15
Weatherproof housing
NOTICE
Damage to the sensor!
The weather protection housing is required during operation outdoors.
NOTICE
Restricted scanning range!
Using the weatherproof housing restricts the field of vision of the TiM35x/TiM36x to a full
extent of 210°.
Procedure for mounting the weatherproof housing
1. Lock and mount the TiM35x/TiM36x in the mounting kit as desired; see
Chapter Procedure for mounting the TiM35x/TiM36x, Page 14
2. Mount the spacer plate
3
.
3. Slide the weatherproof housing
1
over the TiM35x/TiM36x in the mounting kit.
4. Secure the weatherproof housing to the TiM35x/TiM36x using the fixing screws
2
.
5. Mount the mounting bracket horizontally or vertically on a base using suitable screws
4
.
180
69,5
17,5
60
127
103
47,5
1 2
3
4
All dimensions in mm