Table 36: Signal assignment of adapter cable with open end
Pin
Signal
Function
Wire color / charac‐
ters
1
–
Shield
Gray
2
V
S
Supply voltage
Red +
3
GND
Ground
Blue –
4
–
–
–
5
–
–
–
14.4.3
CDB650-204 or CDM420-0006 to CAN network connection module
Adapter cable
Part no. 6021166 (5 m), unshielded
Ambient temperature range:
For fixed installation: –40 °C to +70 °C, for mobile installation: –20 °C to +70 °C
ð
1
4
3
5
2
1
2
Figure 43: Adapter cable, part no. 6021166 (5 m) for connecting the connection module to the
CAN network
1
Female connector, M12, 5-pin, A-coded (view from front)
2
Illustration may differ
Table 37: Pin, signal and wire color assignments for the adapter cable with open end
Pin
Signal
Function
Wire color
1
–
Shield
–
2
V
S
Supply voltage
Red
3
GND
Ground
Black
4
CAN H
CAN bus (IN/OUT)
White
5
CAN L
CAN bus (IN/OUT)
Blue
14.4.4
Host interface RS-232 via CDB/CDM connection module to host (PC)
Device
Connection module
RFU63x
CDB650-204, CDM420-0006, -0007
RFU65x
CDB650-204, CDM420-0006, -0007
Adapter cable
Part no. 2020319 (3 m), unshielded
Ambient temperature range:
For mobile installation: –5 °C to +90 °C, for fixed installation: –30 °C to +90 °C
ANNEX
14
8014335/ZTL9/2018-10-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
101
Subject to change without notice