NOTICE
Quickstart mode is not intended to be used during normal operation. It requires read
cycle triggering to be configured in the object trigger control settings in SOPAS ET.
Operating mode: Read mode
Table 19: Function of the “process feedback” status indicator in read mode
Color
Behavior
Status
Blue
Lights up for the dura‐
tion of the in-progress
reading interval
Read operation was started by an external or internal
trigger source, device has started an internal reading
interval (event)
Green
Lights up briefly
Device has ended the internal reading interval.
Transponder detected and optionally selected condi‐
tion(s) met -> Good Read (event)
Red
Lights up briefly
Device has ended the internal reading interval.
Transponder not detected or optionally selected condi‐
tion(s) not met -> No Read (event)
RFU65x only:
Direction of movement of the transponder in the UHF field
Cyanogen
Lights up briefly
Direction of passage: from plus (+) to minus (–)
Pink
Lights up briefly
Direction of passage: from minus (–) to plus (+)
Indicator trigger source during read mode: combination of “Reading Interval/Good
Read/No Read” (default)
8.1.3
Audible status indicator (beeper)
The beeper (buzzer) can be activated with the SOPAS ET configuration software and its
reporting behavior can be configured.
Depending on the operating mode of the device, the beeper uses different tone
sequences (melodies), lengths or individual sounds to indicate the following results:
•
Fulfillment/non-fulfillment of a configured condition in read operation
•
The completion of device functions started by the user using operating keys or
ended by quitting (confirmation of operation steps)
•
Completion of the processing of received commands (positive or negative confir‐
mation)
Beeper default settings:
Volume: Off, quiet (default), loud.
Read operation: “Good read” output result (device has detected the transponder in the
UHF field and read out the UII).
The sound outlet of the beeper is located under the cover film to the right next to the
label of the display field,
8.1.4
Function buttons
The two Step ▾ and Enter function keys
p
currently have no function.
8
OPERATION
78
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
8014335/ZTL9/2018-10-14 | SICK