background image

www.tyentusa.com

MADE IN KOREA

pH Chart

If the power cord is damaged, it must be replaced by the 

manufacturer, or a similarly qualified Tyent repair person in 

order to avoid a hazard.

This appliance is not intended for use by persons (including 

children) with reduced physical sensory or mental capabilities 

or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance 

by a person responsible for their safety.

Children should be supervised to ensure that they do not 

play with the appliance.

·

·

·

How to Measure pH: Place approximately 2 tablespoons 

(30mL) of test water in a container and add 4 drops of pH 

reagent.  Then, mix well and check the color of the water 

with the pH chart above (The color of the water will change 

according to its pH.)

The user is responsible for improper use of the 
products such as use in any manner for which the 
product was not originally intended and any 
damage that may occur from such improper use.

This product is subject to changes that enhance
its performance without prior notification.

4.0

2.5

11.5

BLACK

LABEL

W A T E R   I O N I Z E R

This product is intended for domestic use only.  
Keep this User Manual handy for easy reference.
Carefully read this User Manual, particularly “all safety warnings.”

User Manual

W A T E R   F O R   W E L L N E S S

Summary of Contents for ACE-13

Page 1: ...sure pH Place approximately 2 tablespoons 30mL of test water in a container and add 4 drops of pH reagent Then mix well and check the color of the water with the pH chart above The color of the water will change according to its pH The user is responsible for improper use of the products such as use in any manner for which the product was not originally intended and any damage that may occur from ...

Page 2: ...ded Use I This device creates functional alkaline ionized water It changes the properties of regular tap water through the use of electrolysis and enables the following changes to occur We are not responsible for any accidents and or malfunctions due to the improper use of this machine Please keep the manual warranty card and a copy of your receipt in a safe place so that it s easily accessible wh...

Page 3: ... half your body weight in ounces For example if you weigh 180 pounds it may be wise to drink 90 ounces every day of water per day This especially applies after you have given your body some time to adjust to the new pH level The recommended drinking level for functional water is 9 5 pH 0 3 It is not recommended to drink functional water above a pH of 10 IIf you wish to store functional water use a...

Page 4: ...stall the drain faucet with suction cup near your sink and adjust the position of the drain faucet s metal spout to drain into the sink Make sure the drain faucet is positioned lower than the unit Do not run the water for longer than 1 hour If the unit won t be used for a long time shut off the valve and unplug the power cord If you hear strange noises smell a burning odor or see smoke unplug the ...

Page 5: ...e weekly This will help to maintain a clean chamber It is normal for condensation to be present on the unit during humid summer months If condensa tion persists despite weather conditions unplug the power cord and refer servicing to qualified service personnel Turn off Cleaning Do not store the unit near chemicals food metals or medication Do not spray water on the main unit Do not clean the unit ...

Page 6: ...dispensed in advance by activating the proximity sensor Fixed quantity discharge function For your convenience the ionizer has the ability to dispense a predetermined amount of water and then stop Presets include 0 5L 1 0L 1 5L These presets can be further adjusted with the jog dial Temperature Sensor Function for Safe Operation If the temperature of the source water exceeds 95 35 the water will s...

Page 7: ...ectional Control The water discharge direction may be adjusted to many diverse angles based on user preference 360 15 minutes Automatic Water Discharge Interruption Function In order to prevent the overflow of water due to user negligence the water discharge is automatically stopped after 15 minutes of use On Screen Filter Usage Indication Super Simple Filter Replacement System The level of filter...

Page 8: ...Tape Front View Water Outlet Unit Proximity Sensor LCD Display Front Cover Door Case Front Case Water Outlet Tube Jog Dial 1 2 3 4 5 6 7 8 Rear View Hanging Groove Rear Case Power Cord 1 2 3 Bottom View Water Inflow Water Outflow 1 2 1 3 2 5 6 7 4 1 2 3 1 3 8 Water Outlet Tube Faucet Diverter pH Testing Solution Bottle 8 2 ft 2 5 m of Hose 2 ft 0 61 m of Gray Hose with Attached Tube Elbow Assortme...

Page 9: ...t leaks If necessary connect the faucet diverter with the appropriate connector to the faucet Be sure all connections are secure but do not overtighten them Option A l Faucet A faucet connection requires a faucet diverter included Option B l Under Sink An under sink connection requires an under sink adapter kit not included or a compatible t valve available from most hardware stores For more infor...

Page 10: ...e water supply either using the faucet diverter or the under sink T connection Note Keep the length from the unit to the faucet under 16 feet 5 meters You may need a pressure pump or a larger size hose if the pressure is too low Be sure to leave a few extra inches centimeters of length so the faucet can still be rotated Inflow Drain Inflow 4 Connect the hose from the inflow hole to the cold water ...

Page 11: ... through an efficient activated absorption method It also eliminates bad smells and any remaining dissolved chlorine Secondary Filter YT20 2nd Filter Recommended filter replacement cycle Every 6 months 0 01 micrometer filtering film filters contaminated materials including ordinary bacteria etc and maintains the minerals in the water ow to Change the Filters H Close Open 1 Shut off the water suppl...

Page 12: ...t the filters after they have been changed CAUTION Filter 1 reset Filter 2 reset ow to Reset the Filters H peration of the Touch Screen O Press the RETURN button to return to the home screen System setup Voice on Voice off Cleaning Eco mode on Eco mode off Alkaline level 1 Alkaline level 2 Alkaline level 3 Fixed qty discharge Purified water Turbo water Acidic level 1 Acidic level 2 Acidic level 3 ...

Page 13: ...nged CAUTION DISPLAY CHANGES LCD display will match the pH level color according to water pH level being used after icon is pressed Turbo Water Dark Red Color Alkaline Water 3 Violet Color Acidic Water 1 Light Yellow Color Acidic Water 2 Light Orange Color Acidic Water 3 Red Color Clean Water Green Color Menu Window 2 LCD Display 3 Operation of the Touch Screen Operation of the Touch Screen F1 RES...

Page 14: ... displayed When this image is displayed the unit is being cleaned which can be done automati cally and or manually Touch Screen Safety Precautions 1 2 It may be difficult to see the screen in direct sunlight Do not use sharp or pointy objects to press the screen After you suspend the water supply to the unit this message will appear before the water outflow stops Press the desired icon on the LCD ...

Page 15: ... choose the fixed amount of water 0 5ℓ 1 0ℓ 1 5ℓ 0 5 1 0 1 5 release Select a desired water mode Water outflow stops automatically Fixed quantity discharge function is released after water comes out When using the Touch Screen When using the JOG DIAL QTY C 0 5 1 0 1 5 0 5 0 2 5 0 Touch the QTY C button Select the fixed amount of water that you need by turning the jog dial Clockwise Increasing by 1...

Page 16: ...The pH value indicated for each level is based on standardized test results which have used average tap water H Level Adjustment p ystem Setup Method S p Press ALKALI pH Press the desired level that you would like to adjust level will highlight in blue 3 4 1 Press the setup icon 2 Press the top left corner of the screen The menu options will fall below the upper part of the screen ALKALI pH Level ...

Page 17: ... 2 Press the top left corner of the screen The menu options will fall below the upper part of the screen Push the RETURN icon for the previous menu screen Voice says Applied Push the RETURN icon again to complete setup Voice says Setup was completed When done push the RETURN icon for the previous menu screen Voice says Applied Then push the RETURN icon again to leave System Setup Voice says Setup ...

Page 18: ...ss the setup icon 2 Press the top left corner of the screen The menu options will fall below the upper part of the screen Push the RETURN icon for the previous menu screen Voice says Applied Push the RETURN icon again to complete setup Voice says Setup was completed If you push the UP DOWN icon the digital number will increase or decrease by one level Press TIME 3 Press the setup icon 2 Press the ...

Page 19: ...n again to complete setup Voice says Setup was completed Set the Sleep mode timer to your preferred time Power save mode is enabled when not in use during the set amount of time 3 Push the RETURN icon for the previous menu screen Voice says Applied Push the RETURN icon again to complete setup Voice says Setup was completed Touch the level that you would like to be triggered with the proximity sens...

Page 20: ...edetermined volume of water is poured or you can choose to have the cleaning cycle run at a certain time of the day Note The actual cleaning cycle will not start on its own Instead the unit will wait until the next time that you use the machine and it will begin then You can set up the cleaning cycle as a time You can automatically start cleaning at the set time every day 3 Press DISPLAY 2 1 Press...

Page 21: ...ect the ECO icon 2 3 1 Press the top left corner of the screen The menu options will fall below the upper part of the screen Turn on off ECO Mode by selecting the ECO icon in this sequence When ECO Mode is active the unit consumes less power by going to sleep when not in use and displaying the time The period before the unit goes to sleep if ECO is active is set under SLEEP in System Settings If v...

Page 22: ...very 24 hours at a time of your choosing For more information see Cleaning Mode Settings on Page 38 Auto Cleaning 15 00 Manual Cleaning Manual Cleaning 15 seconds is performed whenever desired by simply touching the icon URBO Function T The TURBO function allows you to create strong alkaline and acidic water These types of water are ONLY to be used for cleaning sanitizing and disinfecting purposes...

Page 23: ...ed screen 4 Hot water nit Specifications U To ensure the best functionality there may be some minor changes without notice 11 Max 220W 13 Max 220W YT22 4TL13D YT22 4TL11D Water Cell Plate Materials Water Ionizer 100 130 V 200 240 V 50 60 Hz 4 35ºC 39 95ºF 0 1 0 5 MPa 3 Alkaline 1 Neutral 3 Acidic Turbo User adjustable pH levels control Dual 01 Micron Filtration System LCD filter replacement and an...

Page 24: ... supply is closed Open the Valve Stretch out the hose Change the filter Contact us to install a water pump Wait until water comes out of the water supply pipe Only purified water is extracted Contact us to install a pressure reducing valve Check whether the flow rate is high 5 kgf or faster 46 47 Product Warranty Troubleshooting Troubleshooting Product Warranty Unit leaks Check the filter for prop...

Reviews: