Figure 9: Settings
1
Sensor flipped upside down:
0 => Positive positions on cable outlet side
1 => Positive positions on display side
2
Minimum track width: Smaller tracks are ignored
Maximum track width: Wider tracks are ignored
Typical track width: Specification of the typical track width makes it possible to
output the correct line center point even at the edge of the reading window
3
Missing line readings: If the track is not detected (contamination), the last
detected line center point is output for a defined number of sensing processes
4
CANopen node ID: Setting of the node ID: Default value is 10
CANopen bit rate: Setting of the bit rate. Default value is 125K
TPDO/Event period: Setting of the TPDO/event period
5
Output of the three line center points, the number of detected tracks (status) as
well as the read code.
8.3
Operation via CANopen
CANopen object directory
This chapter contains information on integration of the sensor using CANopen.
All sensor functions can be accessed via the CANopen interface. All settings can be
configured in this interface. The EDS file can also be found at
www.sick.com/ols10
.