Table 8: NodeID and baud rate settings
Parameter
Description
NodeID
Setting of the NodeID
Options: Node ID:
1 to 127 (0 is generally assigned to the master)
Factory setting: 10
Baud
Setting of the baud rate
Options:
10 kbit/s, 20 kbit/s, 50 kbit/s, 100 kbit/s, 125 kbit/s, 250 kbit/s,
500 kbit/s, 800 kbit/s, 1,000 kbit/s
Factory setting: 125 kbit/s
Configuring NodeID
Press and hold the SET pushbutton for at least 2 seconds to access the menu. Select
the “Setting” option: Menu path: Setting → CAN → NodeID
Configuring the baud rate
Press and hold the SET pushbutton for at least 2 seconds to access the menu. Select
the “Setting” option: Menu path: Setting → CAN → Baud
8.1.7
Device reset (Reset) parameter
Performing a reset
Table 9: Reset
Parameter
Description
Reset
Perform a reset.
Options
•
Yes: Perform a reset.
•
No
Factory setting
•
No
1
Select the “Reset” parameter in the “Settng” menu.
2
Select the “yes” option.
3
Press the
pushbutton to reset the device to its initial state. Press the
pushbutton to cancel the process.
8.1.8
Info menu
The IP address, serial number and software version parameters can be viewed in the
Info menu.
The respective values are displayed after
(parameter selection) is pressed.
8.2
Operation via TCP/IP
Configuration, operation and diagnostics of the OLS10 Optical Line Guidance Sensor
can be performed using the Ethernet interface as an alternative to manual operation
via the operating and display elements on the device. SICK AG offers a configuration
and diagnostic interface via the web server integrated in the sensor in order to activate
or evaluate the OLS10 via Ethernet TCP/IP. This can be called up by a PC or an HMI with
a web browser.