12
Technical data
NOTE
The relevant online data sheet for the OLS10, including technical data, dimensions, and
connection diagrams, can be downloaded, saved, and printed at
www.sick.com/ols10
.
12.1
Optics / Features
Table 20: Optics / Features
Light sender
1
Blue LED
Wavelength
450 nm
Light spot size
180 mm x 11 mm
Track field of view +/-90 mm
Code field of view +/-50 mm
Sensing distance
100 mm
Sensing distance tolerance ± 10 mm
Sensing rate
10 ms (CAN), 20 ms (Ethernet)
Bar code types
2/5 interleaved
Module width (min.)
≥
1.5 mm
Track radius (min.)
≥
0.5 m
Initialization time
< 10 s
1
Average service life 100,000 h at TU = +25 °C.
12.2
Supply
Table 21: Supply
Supply voltage U
V
1
12 V DC … 30 V DC
Power consumption (with‐
out load)
< 6 W
Residual ripple
< 5 V
ss
within permitted supply voltage U
V
(must not exceed or be
less than the U
V
tolerances.)
1
Limit values: Max. 8 A for operation in a short-circuit protected network
12.3
Interfaces
Table 22: Interfaces
CANopen
Ethernet
Configuration and process interfaces
12.4
Outputs
Table 23: Outputs
Q1, Q2 switching outputs
PNP
•
HIGH = U
V
– ≤ 2 V
•
LOW < 0.5 V
Circuit protection
Output Q1 + Q2 overcurrent and short-circuit protection (see Table
1)
Maximum output current
< 100 mA (total I
OUT
= Q1 + Q2)
TECHNICAL DATA
12
8022017.10HG/2018-07-18 | SICK
O P E R A T I N G I N S T R U C T I O N S | OLS10
37
Subject to change without notice