Table 5: Ethernet connection diagram, M12 female connector, 4-pin, D-coded
Tx+
Rx+
Tx–
Rx–
1
2
4
wht/grn
ora
wht/ora
grn
3
M12 (D-coded)
1
4
2
3
Table 6: Ethernet female connector description
Pin
Marking
Wire color
Description
1
Tx+
White/Orange
Send data signal, not inverted
2
Rx+
White/Green
Receive data signal, not inverted
3
Tx-
Orange
Send data signal, inverted
4
Rx-
Green
Receive data signal, inverted
6.3
Connecting the supply voltage
The sensor must be connected to a voltage supply with the following properties:
•
Supply voltage DC 12 V ... 30 V (stabilized safety extra-low voltage (SELV/PELV) as
per current standard EN 60950-1)
•
Electricity source with at least 5 W power
Protecting the supply cables
To ensure protection against short-circuits/overload in the customer’s supply cables,
the wire cross-sections used must be appropriately selected and protected.
The following standards must be observed in Germany:
•
DIN VDE 0100 (part 430)
•
DIN VDE 0298 (part 4) and/or DIN VDE 0891 (part 1)
Electrical connection of OLS10
•
Ensure the voltage supply is not connected.
•
If necessary, turn the swivel connector into the desired position as shown in the
figure.
1
2
•
Connect the sensor according to the connection diagram.
6.4
CAN connection
We recommend connecting the ground cable to the CANopen communication interface
as a reference.
If there is no separate CAN GND in the system, this pin is to be connected to the FE.
6
ELECTRICAL INSTALLATION