7
Operation
7.1
General notes
If the device is not able to perform a measurement even though the measuring object is
within the specified measuring range, the alignment should be checked and optimized
if necessary
see "Mounting the device depending on application", page 21
. In general,
adjusting the measuring rate can increase the measuring ability for very dark objects,
for example.
To prevent EMC interference, please observe the wiring instructions.
7.2
Control elements and status indicators
7.2.1
Indicator lights
12
3
Figure 27: OD5000 control panel
1
Communication LED (link)
2
Status LED (power)
3
Cover screw for reset pushbutton
Table 8: Meaning of the indicator lights
Indicator
Status
Color
State
Communication LED (link)
Ö
Green
Ethernet communication is
active
Status LED (power)
Ö
Blue
Laser off
Ö
Red
Invalid measurement
O
Red
Measured value is in the
positive value range
O
Orange
Measured value is in the
negative value range
O
Green
All active outputs have a
high signal / no output
active
Ö
White
“Find me” is active
Ö
Flashing
O
Permanently on
7
OPERATION
28
O P E R A T I N G I N S T R U C T I O N S | OD5000
8021391//2017-10-06 | SICK
Subject to change without notice