7.3.8
I/O settings input (MF)
Figure 48: Tab showing the overview of the I/O settings of input (MF)
7.3.8.1
Setting the polarity
This is where the polarity is set for the external input terminal.
Table 15: Input terminal settings
Setting
Meaning
High
Switches on when input is detected
Low
Switches off when input is detected
High (N.O.) is set by default.
7.3.8.2
Setting the switching function
This is where the function is set for the external input terminal.
Table 16: Switching function settings
Setting
Meaning
None
Input (MF) is not used (input is ignored)
Laser off
Laser is switched off during input
Hold function ON/reset
Used as hold input/reset input when the hold function is activated
For Peak Hold/Bottom Sample Hold: Hold input
For Auto Peak Hold/Auto Bottom Hold: Reset input
Start process recording
Used as a recording input
Recording is carried out when activated. When the specified
amount of saved entries is reached, the recording is stopped and
a file is created.
If the input setting is set to OFF during the recording, the process
is paused and a file is created using the data saved up until that
point.
Measured value offset
Used as an Offset or as an Offset Release Input
Less than 1 s: Offset
1 s or more: Offset compensation
The default mode is
None
.
7
OPERATION
46
O P E R A T I N G I N S T R U C T I O N S | OD5000
8021391//2017-10-06 | SICK