If the settings are not automatically defined then the same speed must be set as is set
for the AOD1. The following values are possible:
•
9.6
•
19.2
•
38.2
•
57.6
•
115.2
•
230.4
•
312.4
•
468.8
•
500.0
•
625.0
•
833.3
•
937.5
•
1,250 (default value)
7.3.10.2
Network settings
Ethernet settings are also defined from the Communication tab.
MAC address
The device-specific MAC address is displayed in this field.
IP address
The device IP address is defined in this field.
The default value is 192.168.0.01.
Addressing mode
The user can choose between a static IP address and DHCP (default value) in this field.
Subnet mask
The device subnet mask is defined in this field.
The default value is 255.255.255.0.
Standard gateway
The standard gateway of the device is defined in this field.
The default value is 0.0.0.0.
Accurate time synchronization
A device of the OD series is defined as a time server in this field. This allows the inter‐
nal clock within all the connected sensors to be synchronized precisely via the standar‐
dized precision time protocol (PTP). In this function, a device of the OD series must be
defined as a master; all additional sensors must be defined as a slave.
This procedure is necessary when
Synchronous
or
Anti interference
is set as the synchroni‐
zation mode.
Table 17: Accurate time synchronization modes
Mode
Meaning
Off (default value)
Function has been deactivated
Master
Device is defined as master
Slave
Device is defined as slave