ELECTRICAL INSTALLATION
5
Electrical installation
5.1
Overview of the installation steps
•
Connect the power supply of the NAV210.
•
Wire the switching outputs (depending on application).
•
Connect the PC temporarily (configuration).
•
Wire the data interface for operation.
5.2
NAV210 connections
•
The NAV210 has 2 multi-pin M12 round connectors. The connections are located on the
corresponding male or female connectors.
•
The NAV210 has an M8 round connector on the front of the device to connect to the
RS-232 interface of a PC. This interface is only used for configuration and must not be
wired permanently.
NAV210: M12 × 8 „Power + I/O“ connection, female connector
Table 9: Pin assignment of the „Power + I/O“ connection on the NAV210
M12 × 4 “Ethernet” connection, female connector
Table 10: Pin assignment of the “Ethernet” connection on the NAV210
NOTE:
Only authorized personnel are allowed to perform electrical installation work.
▸
Do not open the housing.
▸
Observe the current safety regulations when working on electrical systems.
Disconnect the power to the system!
The system could inadvertently start while you are connecting the device.
▸
Make sure that the entire system is disconnected from the power supply during the
electrical installation work.
Pin
Signal
Funktion
1
V
S
heat
Heating supply voltage
2
V
S
Supply voltage
3
GND heat.
Ground for heating
4
OUT1_A
Digital output 1, contact A
5
OUT2_A
Digital output 2, contact A
6
OUT3_A
Digital output 3, contact A
7
GND
Ground
8
OUT1..3_B
Digital output 1..3, contact B
2
1
8
7
6
5
4
3
Pin
Signal
Function
1
Ethe
Ethernet interface
2
Ethe
Ethernet interface
3
Ethernet_TX–
Ethernet interface
4
Ethernet_RX–
Ethernet interface
1
2
4
3