O P E R A T I N G I N S T R U C T I O N S | NAV210
Subject to change without notice
5
ELECTRICAL INSTALLATION
5.4
Carrying out the electrical installation on the NAV210
5.4.1
Auxiliary means
•
Tool
•
Digital measuring device (current/voltage measurement)
5.4.2
Connecting to the auxiliary and Ethernet interface of the NAV210
Pre-assembled cables are available for configuring the NAV210 via the auxiliary serial
interface and the Ethernet interface,
5.4.3
Connecting to the Power + I/O interface of the NAV210
Pre-assembled cables can be ordered as accessories for connection to the M12 round
connector. These cables consist of the round connector and a 5, 10, or 20 m cable with an
open end,
“Power + I/O” connection on the NAV210
WARNING:
▸
Lay all cables so that there is no risk of tripping and all cables are protected against
damage.
NOTE:
Only connect the
NAV210
to the designated M12 round connector.
Pin
Signal
Function
Color of lead
1
VS heat
Heating supply voltage
White
2
VS
Supply voltage
Brown
3
GND heat
Ground for heating
Green
4
OUT1_A
Digital output 1, contact A
Yellow
5
OUT2_B
Digital output 2, contact A
Gray
6
OUT3_A
Digital output 3, contact A
Pink
7
GND
Ground
Blue
8
OUT1..3B
Digital output 1..3, contact B
Red
Tab. 12:
Pin assignments and lead color assignments of cables no. 6036153, no. 6028420,
no. 6036154
8-pin M12 female connector,
A-coded (front view)
Illustration may differ
2
1
3
5
4
6
7
8
...