Electrical installation
68
© SICK AG · Germany · All rights reserved · Subject to change without notice
8012471/ZN27/2017-06-09
Operating Instructions
LMS1xx Laser Measurement Sensors
Chapter
6
Important
The OUT1 B, OUT2 B and OUT3 B connections are internally connected to each other.
“Ethernet” connection
“AUX” connection
Pin
Signal
Function
1
TX+
Tran
2
RX+
R
3
TX–
Transmitter–
4
RX–
Receiver–
Tab. 20:
LMS10x: Pin assignment of the “Ethernet” connection (4-pin M12 female connector, D-coded)
2
1
3
4
Pin
Signal
Function
1
Reserved
Do not use!
2
RxD AUX
Receiver RS-232 (auxiliary interface)
3
GND RS
Ground RS-232
4
TxD AUX
Transmitter RS-232 (auxiliary interface)
Tab. 21:
LMS10x: Pin assignment of the “AUX” connection (4-pin M8 female connector)
1
2
4
3