Mounting
56
© SICK AG · Germany · All rights reserved · Subject to change without notice
8012471/ZN27/2017-06-09
Operating Instructions
LMS1xx Laser Measurement Sensors
Chapter
5
5.2.4
Select mounting location
Risk of dysfunction due to overheating or dazzle!
Direct sunlight can increase in the temperature inside the LMS1xx in an inadmissible way.
Mount the LMS1xx such that it is not exposed to direct sunlight (if necessary fit canopy).
To avoid a dazzle by the device itself, do not install the device with view of glass or
stainless steel surfaces.
5.3
Mounting steps
Special features to note during mounting:
Mount the LMS1xx such that it is protected from moisture, dirt and damage.
Ensure that the entire field of view of the LMS1xx is not restricted.
Mount the LMS1xx such that the indicators are easy to see.
Always mount the LMS1xx so that there is still enough space for mounting and removing
the system connector.
Avoid excessive shock and vibration loading on the LMS1xx.
In applications with heavy vibration, prevent the fixing screws from coming loose by
using screw locking devices (see
section 10.1 “Data sheet LMS1xx/LMC1xx laser
measurement sensor” on page 91
).
Regularly check the tightness of the fixing screws.
Pay attention to the maximum torque of the M5 fixing screws on the LMS1xx of max.
5.9 Nm.
The LMS1xx can be fastened in the following ways:
Mounting
Remark
For mounting see ...
Direct mounting
Without mounting kit
With mounting kit 1a (part no. 2034324) or
kit 1b (part no. 2034325)
and
With mounting kit 2 (part no. 2039302) and
kit 3 (part no. 2039303)
Only in conjunction with mounting kit 1a or 1b
With weather protection hood 190°
(part no. 2046459)
+ standard mounting kit (part no. 2046025)
+ quick-action mounting kit (part no. 2046989)
With weather protection hood 270°
(part no. 2046458)
+ standard mounting kit (part no. 2046025)
+ quick-action mounting kit (part no. 2046989)
Tab. 17:
Mounting options for the LMS1xx