Chapter
6
6.3
Preparing the electrical installation
6.3.1
Supply voltage
For commissioning and operating the LMS1xx, type-dependent the following power supply
voltages as per IEC 60 364
4
41 as well as power drains of the custome-specific power
supply unit are required:
For recommended fuse values, please see
Section “Protection of Supply Cables” on
.
Use safety transformer
The output circuit of the power supply must be safely electrically isolated from the input
circuit, this feature is normally provided by a safety transformer in accordance with IEC 742
(VDE 0551).
6.3.2
Wire cross-sections
Wire all connections with copper cables!
Use the following wire cross-sections:
See also
Section 10.1 “Data sheet LMS1xx/LMC1xx laser measurement sensor” on
.
Device
Power supply voltage
Power drain
LMS10x
LMS11x
LMS15x
DC 10.8 V … 30 V
LMS100: Typcial 10 W
LMS111: Typcial 55 W with maximum heating performance
LMS151: Typcial 55 W with maximum heating performance
LMS12x
LMC12x
LMS13x
LMS14x
LMS173
LMS182
LMC13x
DC 9 V … 30 V
LMS12x: Typcial 10 W
LMC12x: Typcial 10W
LMS13x: Typcial 55 W with maximum heating performance
LMS141: Typcial 55 W swith maximum heating performance
LMS173: Typcial 10 W
LMS182: Typcial 55 W with maximum heating performance
LMC13x: Typcial 55 W with maximum heating performance
Tab. 27:
Power supply voltages and power consumptions of LMS1xx
Connection of
Wire cross-sections
Power supply voltage
At least 0.25 mm², if local power supply (power supply unit) in the
immediate vicinity
At least 1.0 mm² at maximum cable length of 20 m, if connection is
made to an existing DC 24 V power supply
Switching outputs
At least 0.25 mm², maximum cable length 50 m with 0.5 mm²
Data interfaces
At least 0.25 mm²
Tab. 28:
Required wire cross-sections