![SICK Lector64x Flex Operating Instructions Manual Download Page 94](http://html1.mh-extra.com/html/sick/lector64x-flex/lector64x-flex_operating-instructions-manual_1263971094.webp)
Characteristic data of the digital outputs
Table 39: Characteristic data of the digital outputs “External output 1” and “External output 2”
Type
Switching
Switching behavior
PNP switching to supply voltage V
S
Default settings in the device: no function, logic: not inverted (active
high)
Properties
•
Short-circuit pro temperature protected
•
Not electrically isolated from V
S
Electrical values
0 V ≤ V
out
1)
≤ V
S
(V
S
− 1.5 V) ≤ V
out
≤ V
S
at I
out
2)
≤ 100 mA
1)
Output voltage
2)
Output current
NOTE
Assign the functions for the external digital outputs in the device using a configuration
tool, e.g., the SOPAS ET configuration software.
13.4
Licenses
SICK uses open source software which is published by the rights holders under a
free license. Among others, the following license types are used: GNU General Public
License (GPL version 2, GPL version 3), GNU Lesser General Public License (LGPL), MIT
license, zlib license and licenses derived from the BSD license.
This program is provided for general use without warranty of any kind. This warranty
disclaimer also extends to the implicit assurance of marketability or suitability of the
program for a particular purpose.
More details can be found in the GNU General Public License. View the complete
license texts here:
. Printed copies of the license texts are
also available on request.
13
ANNEX
94
O P E R A T I N G I N S T R U C T I O N S | Lector64x/65x Flex, Lector65x Dynamic Focus
8016185/19E9/2020-10-21 | SICK
Subject to change without notice