Removing the memory card from the device:
NOTICE
Risk of damage to the memory card!
b
To avoid damaging the microSD memory card, make sure the device is
de-ener‐
gized
when you insert or remove the card. For this purpose, disconnect the device
from the supply voltage.
1.
Switch off the supply voltage to the device.
2.
Undo the screws on the hinged cover.
3.
Making sure it is in the correct position, push the memory card into the slot until
it is released. When doing this, position the contacts so that they are facing to the
rear and upwards, see the card symbol on the device.
4.
Remove the memory card.
5.
Close the hinged cover. Make sure that the cover is completely flush with the
housing.
6.
Tighten the screws on the hinged cover.
7.
Switch on the supply voltage for the device.
3.3.4
Product features and functionality
The Lector64x and Lector65x image-based code readers are available in the following
device variants:
•
Lector64x Flex, Lector65x Flex (basic device)
•
Lector65x Dynamic Focus (complete device)
The basic device (Flex device variant) is equipped with a C-mount thread. The user
compiles the basic device depending on the application case. We recommend only
using products from SICK as components. Optionally, the user can order an applica‐
tion-specific optics kit (lens, integratable VI88I illumination unit, spacer, optics protec‐
tive hood) separately as an accessory. The complete device (Dynamic Focus device
variant) is already equipped with a pre-assembled lens and a pre-assembled integrated
illumination unit.
The intuitive device equipment – featuring function buttons, auto-setup, laser alignment
aid, an acoustic feedback signal, and a green feedback LED – reduces the amount of
work required for training and installation.
3
PRODUCT DESCRIPTION
22
O P E R A T I N G I N S T R U C T I O N S | Lector64x/65x Flex, Lector65x Dynamic Focus
8016185/19E9/2020-10-21 | SICK
Subject to change without notice