Functions
An inserted memory card serves as a local external storage medium for the device
outside the internal device memory,
see "Initial commissioning", page 50
.
The device can execute the following functions using the memory card:
•
Cloning function: storage of the currently valid parameter set
Automated additional storage of the parameter set with the configuration data of
the device on an external storage medium that is quickly accessible to the user.
This takes place as part of the recommended backup concept for the parameter
sets of the 4Dpro devices. The externally stored parameter set is also updated
automatically each time the currently valid configuration data is permanently
saved. For devices without a card slot, the optional CMC600 cloning module,
installed in the CDB/CDM connection module, also offers the same external stor‐
age option in addition to other functions. The otherwise necessary connection
of a computer to the device in order to manually save the parameter set is not
required with this data backup method. The cloning function provides the means,
for example in the event of a device fault, for a manual transfer of the currently
valid parameter set to an exchange unit of the same type.
Automated saving to the external storage medium is triggered by saving the
parameter set in the device with the
Permanent
option, e.g., via the SOPAS ET
configuration software.
•
Firmware download (update)
For information on prerequisites, and the procedure for downloading and updating
the firmware, see the SICK Support Portal.
•
Optional: Image is saved for a failed read (read result: No Read).
•
For information on other available functions, see “Overview of SOPAS Parame‐
ters” in the online help of the device (part number: 8020322,
•
Other functions available on request.
When saving a parameter set for the first time, use an empty MicroSD memory card.
b
Check and, if necessary, delete the contents of the current memory card on the
computer.
Device access to the memory card
NOTE
The device does not directly signal access (read, write) to the memory card.
When saving the parameter set using the
Permanent
option, the
Ready
LED indicates
when the save process has completed:
•
When the device starts saving, the
Ready
LED goes out.
•
When the device has finished saving, the
Ready
LED lights up green again.
NOTICE
Possible data loss!
If the memory card is removed or the supply voltage switched off when saving the
parameter set in SOPAS ET, data may be lost.
b
Do not remove the memory card or switch off the supply voltage while the parame‐
ter set is being permanently changed by saving it with the
Permanent
option in
SOPAS ET.
b
To safely remove the memory card during operation, select the
Remove SD card
option under
Analysis/SD card
in SOPAS ET. Then wait for the feedback from
SOPAS ET.
3
PRODUCT DESCRIPTION
20
O P E R A T I N G I N S T R U C T I O N S | Lector64x/65x Flex, Lector65x Dynamic Focus
8016185/19E9/2020-10-21 | SICK
Subject to change without notice