![SICK Lector64x Flex Operating Instructions Manual Download Page 30](http://html1.mh-extra.com/html/sick/lector64x-flex/lector64x-flex_operating-instructions-manual_1263971030.webp)
6
Selected code resolution
7
Focal length of lens, here for example for f = 35.0 mm
8
Reading off: resultant maximum working distance
9
Reading off: resultant field of view (mm x mm)
Lector65x Flex
Field of view in mm²
1D code
Working distance/focus position in mm
V2D65
2
R
0
300 x 150
600 x 300
700 x 350
800 x 400
1000 x 500
900 x 450
200 x 100
400 x 200
500 x 250
100 x 50
0
V2D65
4
R
300 x 300
600 x 600
700 x 700
800 x 800
1000 x 1000
900 x 900
200 x 200
400 x 400
500 x 500
100 x 100
1
4
5
3
2
f = 12 mm
f = 16 mm
f = 50 mm
f = 75 mm
f = 25 mm
f = 35 mm
0
200
400
600
800
1000 1200 1400 1600 1800 2000 2200
Min. resolution in mm
2D code
0.2
0.3
0.1
0.2
0.4
0.6
0.4
0.3
0.1
0.5
0.5
0.7
0.6
0.7
0.8
0.9
1
Field of view in mm
2
2
Minimum resolution in mm
3
1D code
4
2D code
5
Working distance/Focus position in mm
6
Selected code resolution
7
Focal length of lens, here for example for f = 35.0 mm
8
Reading off: resultant maximum working distance
9
Reading off: resultant field of view V2D65
2
R (mm x mm)
10
Reading off: resultant field of view V2D65
4
R (mm x mm)
5
MOUNTING
30
O P E R A T I N G I N S T R U C T I O N S | Lector64x/65x Flex, Lector65x Dynamic Focus
8016185/19E9/2020-10-21 | SICK
Subject to change without notice