12. With illumination unit variants with LEDs in risk group RG 2: Attach the coun‐
try-specific warning label to the optics protective hood near the light emission,
"Attaching the warning label", page 28
.
5.4.2
Attaching the warning label
Devices and illumination units with LEDs in risk group RG 2 are provided with the
following warning label.
Figure 6: Risk Group 2: CAUTION - Possibly hazardous optical radiation emitted from this product.
Do not look into the lamp during operation. This could damage your eyes. ICE 62471:2006-07;
EN62471:2008-09
The warning label is located on the exterior of the housing of the devices. For the
illumination units, the warning label is located on the outer ring.
The mounted optics protective hood covers the warning label on the illumination unit.
The integrable illumination unit types in risk group RG 2 that are mounted by the user
are therefore accompanied by an additional black and yellow warning label for optical
radiation of risk group RG 2.
The warning sign in available in English and French. Attach the country-specific warning
label in a highly visible location on the outside of the optics protective hood of the
device.
1.
Affix the illumination unit to the device housing.
2.
Manually adjust the focus and aperture of the lens and check these using the
SOPAS ET configuration software.
3.
Attach the protective optics cover and screw it tight.
4.
Attach the warning label to the protective optics cover near the light outlet so that
it is clearly visible.
5.
If the device itself is, for example, integrated into a machine in such a way that
the attached warning label is obscured, attach further clearly visible labels to the
machine close to where the light is emitted.
5.5
Mounting location
5.5.1
Working range
Depending on the device type, the working range is between 50 mm and 2,200 mm.
•
Lector64/65x Dynamic Focus: the device automatically adjusts its focus position
to the working distance with the Auto-Setup function.
•
Lector64/65x Flex: the user manually sets the focus position on the lens.
The field of view is determined by the focus position, the focal length of the lens, and
the working distance. The necessary working distance can be determined from the field
of view diagram,
see "Field of view diagrams", page 29
.
5.5.2
Mounting bracket and reflection prevention
In order to avoid reflections from the surfaces to be scanned, mount the device so that
it is tilted from the perpendicular to the surface.
5
MOUNTING
28
O P E R A T I N G I N S T R U C T I O N S | Lector64x/65x Flex, Lector65x Dynamic Focus
8016185/19E9/2020-10-21 | SICK