Electrical installation
5.4
Connecting the operator display
The operator display mounted in the operator's cab is connected to the voltage supply and
the Ethernet switch inside the control cabinet.
Fig. 33: Connecting the operator display
Pin
Wire no.
Description
POWER
1
1
24 V
2
2
24 V
3
3
GND
4
4
GND
Tab. 7: Operator display –
pin allocation of the connecting cable
Ethernet connecting cable
The Ethernet cable for connecting the display and control cabinet has an angled M12 male
connector (for connection on the display side) and a RJ45 connector (for connection on the
control cabinet).
Fig. 34: Connecting the operator display to the control cabinet
Pin assignment