Start-up and Parameter Settings
FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH
197
Su
bj
ect
to
ch
an
ge
with
ou
t n
otic
e
For operation in HART® bus networks, the polling-address needs a higher value than 0. The
modification of the addressing can only be realized via the HART® bus interface itself.
Changes of the configuration by using the user software SOPAS ET are not supported.
The provided services, commands, telegrams and data types by this module are described
in a separate specification.
4.3.7
Application-specific flow calibration
The measuring precision of the velocity measurement can be improved by a comparison
measurement with reference measuring system still further. The measured values have to
be entered as an offset in the "Adjust factor" window in the "Parameter / Measure Point 1 /
Measure Point Parameter" directory, field "Measuring Point 1 - Application Parameter (I)”
(
For detailed information, see „Interface Documentation FLOWSIC100 Flare“.