134
FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH
Assembly and Installation
Su
bj
ect
to
ch
an
ge
with
ou
t n
otic
e
Terminal data
Terminal
Marking on the processor board
Function
Voltage rating
Ampere rat-
ing
1, 2, 3
com, n.c.
1)
, n.o.
2)
relay 1 (malfunc.)
Indication of malfunction
≅
30 V a.c./d.c.
1 A
4, 5, 6
com, n.c.
1)
, n.o.
2)
relay 2 (maint.)
Indication of maintenance
7, 8, 9
com, n.c.
1)
, n.o.
2)
relay 3 (check.)
Indication of function check
10, 11, 12 com, n.c.
1)
, n.o.
2)
relay 4 (maint.requ.) Indication of maintenance request
13, 14, 15 com, n.c.
1)
, n.o.
2)
relay 5 (limit)
Indication of limit violation
16, 18
din1, gnd
Digital input 1 (active low forced to gnd)
5.5 V d.c.
max. 1 mA
17, 18
din2, gnd
Digital input 2 (active low forced to gnd)
19, 21
din3, gnd
Digital input 3 (active low forced to gnd)
20, 21
din4, gnd
Digital input 4 (active low forced to gnd)
22, 23
+, -
Analog output (20 mA)
max. 22 V d.c.
max. 24 mA
24
gnd
Ground
25, 26
ain1, gnd
Analog input 1
max. 3 V d.c.
22 mA
27, 28
ain2, gnd
Analog input 2
29, 30
+, gnd
Output 24 V d.c.
22 ... 28 V d.c.
3)
31, 32
+24, -24
Power supply bus sender/receiver unit 1 22 ... 28 V d.c.
33, 34
A, B
RS485 interface bus sender/receiver
unit 1
± 5 V
max.
100 mA
35
scr.
Screen (gnd)
36, 37
+24, -24
Power supply bus sender/receiver unit 2 22 ... 28 V d.c.
38, 39
A, B
RS485 interface bus sender/receiver
unit 2
± 5 V
max.
100 mA
40
scr.
Screen (gnd)
41, 42
24 V, gnd
Input voltage supply 24V d.c
22 ... 28 V d.c.
3)
43, 44
24 V, gnd
Output voltage supply 24V d.c.
- 5 V ... +12 V
3)
45, 46
+, -
Input 30 V electr. isolated
47, 48
12 V, gnd
Internal voltage (not planned for use)
3)
49, 50
5 V, gnd
51, 52, 53 tx/A, rx/B, gnd
RS232/485
3)
54, 56
res 1, gnd
Reserve (not planned for use)
55,56
res 2, gnd
57, 60
res 3, gnd
58, 60
res 4, gnd
59, 60
res5, gnd
71, 73
A, gnd
Interface 1
72, 73
B, gnd
74, 76
+Us, gnd
75, 76
-Us, gnd
77, 79
imp+, res 1
78, 80
imp-, res 2